background image

P/N 750301  Page   18

 

 

THE CORRECT HEIGHT OF YOUR PYRAMID STYLE HOOD

 

 

THE BOTTOM OF THE HOOD SHOULD BE 30" MINIMUM TO 36" MAXIMUM ABOVE THE 

COUNTERTOP. THIS WOULD TYPICALLY RESULT IN THE BOTTOM OF THE HOOD BEING 66" 

TO 72"  ABOVE THE FLOOR. THE BOTTOM OF THE HOOD SHOULD NEVER BE MORE THAN 

72" ABOVE THE FLOOR OR MORE THAN 36" ABOVE THE COUNTERTOP. THESE DIMENSIONS 

PROVIDE FOR SAFE AND EFFICIENT OPERATION OF THE HOOD. IF FOR SOME REASON THE 

HOOD IS MOUNTED GREATER THAN 72” FROM THE FLOOR, IT MUST BE 6” WIDER THAN THE 

RANGE.

 

ALL PC MODELS TOP DUCT ONLY.  (NOTE: THE PC HOOD CAN BE DUCTED TO 

THE REAR WITH THE USE OF A 90 DGREE ELBOW (NOT INCLUDED).  CHECK 

PAGE 19 OF MANUAL FOR RECOMMENDED TRANSITIONS.  (ROUND DUCTING 

SHOWN FOR ILLUSTRATIVE PURPOSES.  ACTUAL HOOD MAY VARY)

 

 

BS

-

PC3024 CANNOT ACCEPT THE BS

-

PCIB1200 INTERNAL BLOWER 

 

REAR DISCHARGE

 

TOP  DISCHARGE

 

HEIGHT FROM FLOOR

68"(MIN)-72"(MAX)

167.6cm-182.9cm

COUNTERTOP

HEIGHT ABOVE COUNTERTOP

30"(MIN)-36"(MAX)

76.2CM-91.4CM

Содержание PRO LINE PL30240

Страница 1: ...THE APPLIANCE AND THE CONSUMER IS TO RE TAIN THEM FOR FUTURE REFERENCE 4 PLEASE OBSERVE ALL LOCAL AND NATIONAL BUILDING CODES AND ORDINANCES IF NO LO CAL CODES ARE APPLICABLE PLEASE FOLLOW ALL WIRING...

Страница 2: ...9 Installation of Pro Line Series Dimensions 10 Site Preparation 11 The Correct Height 12 Duct Information 13 Blower Installation 14 Custom Duct Installation 15 Installation of Pyramid Style Dimensio...

Страница 3: ...G OR SERVICING UNIT SWITCH POWER OFF TO THE UNIT AT THE SERVICE PANEL AND LOCK OUT THE SER VICE PANEL IF THE SERVICE PANEL CAN NOT BE LOCKED OUT PLEASE AFIX A WARNING DEVICE PROMINENTLY SUCH AS A TAG...

Страница 4: ...T OR METAL TRAY THEN TURN OFF THE BURNER TAKE CARE TO AVOID AND PREVENT BURNS IF FLAMES DO NOT EX TINGUISH EVACUATE THE PRMISES AND CALL THE FIRE DEPARTMENT NEVER HANDLE OR PICK UP A FLAMING PAN DO NO...

Страница 5: ...understands meets and exceeds customer expectations We establish and maintain an environment that encourages all employees to pursue continuous improvement in qual ity and productivity Our quality pol...

Страница 6: ...ing adds a touch of elegance to your kitchen like no other appliance can What s more this high quality high performance appliance is backed by our professional service network from coast to coast to p...

Страница 7: ...THE CONTAINER IS NOT UPRIGHT MAJOR DAM AGE CAN OCCUR TO YOUR APPLIANCE IF DAMAGE IS DISCOVERED DO NOT REFUSE DELIVERY CONTACT THE DEALER AND FILE APPROPRIATE FREIGHT CLAIMS SAVE ALL PACKAGING MATERIA...

Страница 8: ...4 Stainless Steel Baffle Filters Two 2 Pre Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram PL48240 PL54240 24 Depth No blower Sold and Packaged Separately Six 6 Stainle...

Страница 9: ...Installed Lights Lid for Electrical Box Use and Care Manual with Wiring Diagram Duct cover sold packed in separate box 2 of2 PC48240 PC54240 24 Depth No blower Sold and Packaged Separately Six 6 Stain...

Страница 10: ...TION FOR THE ELECTRICAL CONNECTION IS LOCATED NEAR THE REAR CENTER OF HOOD 2 5 FROM HOOD BOTTOM ELECTRICAL REQUIREMENTS 15 AMPS AT 120 VOLTS LIGHT BULBS ARE PAR16 60 WATT HALOGEN BULBS ARE OPERATED BY...

Страница 11: ...G THE LINE SO YOU MAY REST THE HOOD ON IT WHILE INSTALLING MARK A CENTER LINE ON THE WALL EQUAL TO THE ENTIRE HEIGHT OF THE HOOD TO ASSIST WITH THE PROPER DUCT ALIGNMENT AND HOOD PLACEMENT DETERMINE S...

Страница 12: ...FICIENT OPERATION OF THE HOOD IF FOR SOME REASON THE HOOD IS MOUNTED GREATER THAN 72 FROM THE FLOOR IT MUST BE 6 WIDER THAN THE RANGE ALL PL MODEL HOODS HAVE THE FLEXIBILITY TO EITHER DUCT FROM THE TO...

Страница 13: ...T SIZE TO 8 FOR OPTIMAL PERFORMANCE IMPORTANT PLANNING INFORMATION PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM ALL CFM S ARE BASE...

Страница 14: ...1 INSTALLATION OF BS IBPL1200 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1 REMOVE SHIPPING BRACKET FROM HOOD DO NOT DISCARD SCREWS FOR FAN 1 1 INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE...

Страница 15: ...HOOD THAT CORRESPOND WITH THE SMALL HOLES ON THE DUCT COVER INSTALL HOOD TO CORRECT HEIGHT BE CAREFUL TO LEAVE 12 FOR DUCT COVER SLIDE DUCT COVER OVER TOP OF HOOD MAKE SURE SMALL HOLES IN DUCT COVER...

Страница 16: ...P N 750301 Page 16 DIMENSIONS OF THE PYRAMID STYLE SERIES HOOD...

Страница 17: ...EQUAL TO THE WIDTH OF THE HOOD ALONG THE LINE SO YOU MAY REST THE HOOD ON IT WHILE INSTALLING MARK A CENTER LINE ON THE WALL EQUAL TO THE ENTIRE HEIGHT OF THE HOOD TO ASSIST WITH THE PROPER DUCT ALIGN...

Страница 18: ...D EFFICIENT OPERATION OF THE HOOD IF FOR SOME REASON THE HOOD IS MOUNTED GREATER THAN 72 FROM THE FLOOR IT MUST BE 6 WIDER THAN THE RANGE ALL PC MODELS TOP DUCT ONLY NOTE THE PC HOOD CAN BE DUCTED TO...

Страница 19: ...10 IMPORTANT PLANNING INFORMATION PROPER INSTALLATION OF DUCTING IS EXTREMELY INPORTANT FOR OPTIMAL PERFORMANCE OF YOUR BLUESTAR VENTILLATION SYSTEM ALL CFM S ARE BASED ON TESTS AT 0 1 STATIC PRESSURE...

Страница 20: ...INSTALLATION OF IBS IBPC1200 INTERNAL BLOWER KIT REFER TO WIRING DIAGRAM 1 REMOVE SHIPPING BRACKET FROM HOOD DO NOT DISCARD SCREWS FOR FAN 1 1 INSTALL BLOWER BRACKET WITH THE SCREWS REMOVED FROM THE S...

Страница 21: ...VER TOP FOR THE DESIRED LOWERING POINT BY SUBTRACTING 15 FROM THE TO TAL HEIGHT NEEDED 3 USE THE RETAINING SCREWS TO FASTEN IN PLACE 4 SLIDE THE DUCT COVER IN PLACE AND FASTEN FROM INSIDE CANOPY USING...

Страница 22: ...P N 750301 Page 22 WIRE DIAGRAM FOR BLUESTAR PLAND PC HOODS...

Страница 23: ...THE FINISH DO NOT DISASSEMBLE THE BAFFLE FILTER DISASSEMBLY WILL VOID THE WARRAN TY CANOPY DO NOT USE ABRASIVE CLEANERS STEEL WOOL PADS ABRASIVE CLOTHS OR CLEAN ERS WITH CHLORIDES DO NOT ALLOW GREASE...

Страница 24: ...over Products installed outside the U S or Canada This Warranty does not apply to gas type conversions on cooking appliances not completed by a certified gas technician licensed plumber or certified B...

Страница 25: ...rranty of any kind for floor models Limited Warranty on Product Refurbished Refurbished Products are covered by a six 6 months limited functional parts and labor warranty with proof of installation as...

Страница 26: ...atmosphere loss of electrical power to the Product for any reason or other conditions beyond Prizer Painter s control Damage or repairs caused by alteration for outdoor use Damage or repairs caused b...

Страница 27: ...ER SHALL IN NO EVENT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO DAMAGES FOR EXPENSES SUCH AS EXTRA UTILITY EXPENSES SHIPPING COSTS RELATED TO REPAIR OR REPL...

Страница 28: ...tion Date ___________________________ e mail _______________________________________ Installer s Name ___________________________ Telephone ____________________________________ Company _______________...

Страница 29: ...ation Date ___________________________ e mail _______________________________________ Installer s Name ___________________________ Telephone ____________________________________ Company ______________...

Отзывы: