10
Notes on Inverter Mode Behaviour
This device is equipped with multiple safety features to safe-guard use and
device longevity.
- If the electrical load attached to the device is in excess of
the power generator’s maximum power rating, an audible
alarm will sound to alert the user. Once the load significantly
exceeds the power-generator’s load rating the mains output
will cut-off. The power-generator will attempt to restart until
the load is reduced to an acceptable level.
- If the packs report an over-temperature error, the power-
generator will shut down until the pack temperature falls to
an acceptable level.
- When the device charge is empty, the inverter function
will be disabled until the device is charged to at least 5%
capacity.