background image

Содержание PG700

Страница 1: ...Li Ion Portable Power Generator PG700 700W 1150Wh Ruggedised Inverter Power Station Operating Manual Revision 1 0 www blueshape net Printed in Malta 2022...

Страница 2: ......

Страница 3: ...power generator the device This symbol indicates the presence of an electrical shock hazard It is intended to avert users not to open the product as there are no user serviceable parts inside Any for...

Страница 4: ...tach an earthing lead with an M6 ring terminal The other end of the earthing lead must be terminated with an earth rod inserted into the ground or a crocodile clip attached to a conductive earthed str...

Страница 5: ...e if it is apparently damaged or deformed Only connect mains plugs compatible with your device Warning If recharging operation fails to completed even when a specified recharging time has elapsed imme...

Страница 6: ...n level ground Only carry the device from the appropriate carrying handles Do not operate the device with damaged power cords Replace any damaged cords immediately Do not obstruct ventilation always o...

Страница 7: ...d This is an all in one product which also features built in charging capability The PG700 is built in a rugged portable hard case When the lid is closed for storage and handling it can withstand shoc...

Страница 8: ...age and Handling 1 1 2 2 3 3 6 6 5 5 4 4 The PG700 is constructed in a rugged hard case and consists of the following 1 Telescopic Handle 2 Upright Carry Handle 3 Enclosure Lid 4 Roller Wheels 5 Lid L...

Страница 9: ...7 7 8 8 2 2 6 6 The PG700 front facing panel consists of the following 1 Exhaust Fans 2 Silent Charging Switch 3 Front Panel Cap Nuts 4 Charge AC Input Socket 5 Mains Outlet 6 Mains Output Switch 7 I...

Страница 10: ...ging will still work with the mains output active or idle Unless the inverter functionality is required switch off mains output to ensure pack longevity The display will show a charge progress bar and...

Страница 11: ...ating of the power generator The display will show a charge remaining bar and will indicate the estimated time till complete charge depletion In the second display row an indication of the operational...

Страница 12: ...lert the user Once the load significantly exceeds the power generator s load rating the mains output will cut off The power generator will attempt to restart until the load is reduced to an acceptable...

Страница 13: ...onnect a compatible mains cable to socket labelled AC Output 3 Press the switch to the on position Use this mode as necessary unless a mains output is required Switch off the mains output when chargin...

Страница 14: ...emaining Time Low Battery remaining time is less than 10 minutes Warning Waiting for battery to cool Charging is inhibited until the battery temperature is below 35 C Warning Battery thermal limit The...

Страница 15: ...V AC 50 60 Hz Model Dependant Max Continuous AC Power Output 700 W Max Instantaneous AC Power Output 800 W Internal Battery Capacity 1150 1500 Wh Model Dependant Approx Charging Time 7 Hrs Dimensions...

Страница 16: ...he device immediately before use Some self discharge would result if the batteries are charged several weeks in advance of their use However this slight loss can be re charged at any time without any...

Страница 17: ...This page has been intentionally left blank...

Страница 18: ...This page has been intentionally left blank...

Страница 19: ......

Страница 20: ...expenses including transport charges will be borne by us In the case where the failure has been caused by one of the causes explained above repairs shall be billed at a nominal cost Prior to the carry...

Отзывы: