Blueshape CVS8X Скачать руководство пользователя страница 7

7

IPCS and fast charging

The BLUESHAPE CVS8X charger features the highest charging
current for a Li-Ion charger in the broadcasting sector.
This results in currently the shortest possible battery charging time.

BLUESHAPE Li-Ion BV battery series allow fast charging due to
several intrinsic features such as pre-charge protection and cell
balancing; avoiding cell damage and life-cycle shortening, as
demonstrated by the life-cycle performances.

Additionally, the CVS8X charger supports and enhances these
features with 

IPCS

, a 2-step Intelligent Pre-Charge System.

Since fast charging can damage cells if not properly applied,
especially with low voltage (discharged) cells, appropriate care must
be taken. The 2-step procedure implemented by IPCS, initially
boosts very low voltage cells to a state where charge can be applied
with a medium-low current without damage, then starts to charge
with a 300mA current for a while. Finally, when the pack reaches a
reasonable voltage state, it speed-up the charge process by going
to full throttle.

The operation implemented by IPCS is only applied if the prevailing
cells-state need it, and normally takes a few minutes, depending on
the state of discharge of the cells.
The operation implemented by IPCS is outlined in the chart below.

IPCS 2-step Intelligent Pre-charge System

11000

11500

12000

12500

13000

13500

0

3

5

8

10

13

15

18

20

23

Time (min)

Vo

lt

ag

e (

m

V)

0

100

200

300

400

Cur

re

nt (mA)

CURRENT

VOLTAGE

Step-1

Step-2

Содержание CVS8X

Страница 1: ...www blueshape net Printed in Malta 2009 INTELLIGENT BATTERY CHARGER FOR V LOCK LITHIUM ION BATTERIES ONLY Model CVS8X OPERATING INSTRUCTIONS Revision 1 0...

Страница 2: ...nspection or repair Clean only by using a dry cloth Unplug when not in use and avoid power surges Read the supplied instructions thoroughly and keep handy Avoid setting up near heat sources such as fi...

Страница 3: ...INTENDED FOR OPERATION WITH LINE VOLTAGES BETWEEN 100V AND 240V AC AND LINE FREQUENCIES BETWEEN 43Hz AND 60 Hz The equipment is being supplied with a compatible AC mains power cord In the case when th...

Страница 4: ...ED indicator see page 13 for explanation 3 LCD keys 4 LCD display 5 Carrying handle 6 Ventilation inlets 7 Release buttons 8 Battery 3 and 4 charging bays Battery 1 and 2 charging bays on opposite sid...

Страница 5: ...tilation outlets 2 Data connector 3 AUX output connector 13 8V 110W 4 Ventilation inlets 5 Release buttons 6 Battery 1 and 2 charging bays Battery 3 and 4 charging bays are on opposite side 7 AC Mains...

Страница 6: ...toring Pre charge function for protecting heavily discharged cells against high currents until their voltages rise to a safe level Maximum compactness and space utilisation IPCS and CTP Features see n...

Страница 7: ...pecially with low voltage discharged cells appropriate care must be taken The 2 step procedure implemented by IPCS initially boosts very low voltage cells to a state where charge can be applied with a...

Страница 8: ...emperature reaching a high level the charging current is automatically reduced to avoid possible damage caused by internal overheating When the charging speed is reduced the internal temperature start...

Страница 9: ...the AC power cord provided into the charger AC input Plug and switch on the AC mains supply Insert a battery inside any one of the four V plate adapters as shown see picture Observe the LED In additio...

Страница 10: ...y has been unplugged the charger will continue the previous charging sequence and from the same point of interruption PLEASE NOTE THAT THE MAXIMUM LOAD THAT CAN BE CONNECTED TO THE XLR OUTPUT MUST NOT...

Страница 11: ...e indication of the battery status the battery state of charge in percentage the remaining charge time in minutes Please note When batteries other than Blueshape are installed the information displaye...

Страница 12: ...ec 1200sec VOLTAGE TOO LOW RED flashing 500ms ON 500ms OFF BATTERY FAILURE Steady RED PRECHARGE 1 ORANGE flashing 500ms ON 500ms OFF PRECHARGE 2 ORANGE flashing 250ms ON 250ms OFF 4 CONSTANT CURRENT M...

Страница 13: ...if a load is connected and an excessive current is absorbed I 8 2A SHORT CIRCUIT AUX LED Steady ORANGE 3 An Overload condition may occur when the AUX is powered up and an excessive current is drained...

Страница 14: ...vailable Overtemperature protection Available LEDS 3 colour type for BAT1 BAT2 BAT3 BAT4 and AUX LCD 20x4 Blue White backlight Special features IPCS and CTP Auxiliary power 13 8V 110W max Power supply...

Страница 15: ...light loss can be topped up at any time without any degradation of battery performance no memory effect It is recommended to store batteries in a cool and dry place Charging should be done at temperat...

Страница 16: ...h information as possible about the failure being claimed In the event of product failure for which warranty applies we will repair or replace the product free of charge In these cases all expenses in...

Отзывы: