Blueridge BPHP14 Series Скачать руководство пользователя страница 1

507296-01B

Page 1  of 13

Issue 1650

THIS MANUAL MUST BE LEFT WITH THE 

HOMEOWNER FOR FUTURE REFERENCE

Installation and servicing of air conditioning equipment 

can be hazardous due to internal refrigerant pressure 

and live electrical components. Only trained and 

qualified  service  personnel  should  install  or  service 

this equipment. Installation and service performed by 

unqualified  persons  can  result  in  property  damage, 

personal injury, or death.

WARNING

For your safety, do not store or use gasoline or other 

flammable vapors and liquids in the vicinity of this or any 

other appliance. Such actions could result in property 

damage, personal injury, or death.

WARNING

The installation of this appliance must conform to the requirements of the National Fire Protection Association; the 

National Electrical Code, ANSI/NFPA No. 70 (latest edition) in the United States; the Canadian Electrical Code Part 

1, CSA 22.1 (latest edition) in Canada; and any state or provincial laws or local ordinances. Local authorities having 

jurisdiction should be consulted before installation is made. Such applicable regulations or requirements take precedence 

over the general instructions in this manual.

CAUTION

Save these instructions for future reference

INSTALLATION AND MAINTENANCE 

INSTRUCTIONS

BPHP14 

SERIES UNITS

RESIDENTIAL PACKAGED UNITS

Air Conditioners and Heat Pumps

507296-01B

12/2016

Table of Contents

Installation ...................................................................

2

Electrical Wiring ...........................................................4

Duct System ................................................................5

Filters ...........................................................................5

Condensate Drain........................................................5

Sequence of Operation................................................

7

Maintenance ................................................................

9

Wiring Diagrams ........................................................

10

If this unit is to be installed in a mobile or manufactured 

home  application,  the  duct  system  must  be  sized  to 

achieve  static  pressures  within  the  manufacturer’s 

guidelines. All other installation guidelines must also 

be followed. Failure to do so may result in equipment 

damage, personal injury, and improper performance of 

the unit.

WARNING

Manufactured By

Blue Summit LLC

8201 C National Turnpike

Louisville, KY 40214

 

(P) 507296-01B

*P507296-01B*

Содержание BPHP14 Series

Страница 1: ...Code Part 1 CSA 22 1 latest edition in Canada and any state or provincial laws or local ordinances Local authorities having jurisdiction should be consulted before installation is made Such applicable...

Страница 2: ...with any ductwork in the outdoor air stream The outdoor fan is not designed to operate against any additional static pressure Location The unit is designed to be located outdoors with sufficient clea...

Страница 3: ...410A are higher than pressures in units charged with HCFC 22 All service equipment MUST be rated for use with HFC 410A refrigerant WARNING Clearances All units require certain clearances for proper o...

Страница 4: ...ed so that water or moisture cannot be drawn into the unit during normal operation CAUTION Units are factory wired for a 230 volt power supply If power supply is 208 volts it will be necessary to chan...

Страница 5: ...chments 5 Install drain pan overflow switch and wire according to downflow conversion kit instructions Filters Air filters are not supplied with the unit A field provided air filter must always be ins...

Страница 6: ...red for safety while servicing do not open the system disconnect switch Heater Kit Accessory if used The unit is fully equipped for cooling operation without auxiliary heat A heater kit accessory may...

Страница 7: ...send a signal to the defrost control board to start the defrost timing It also terminates defrost when the liquid line warms up to 60 F Figure 7 Defrost Control Board Diagnostic LEDs 24V Terminal Stri...

Страница 8: ...e control board In addition the diagnostic LEDs will indicate a locked out pressure switch after the fifth occurrence of an open pressure switch see Table 3 The unit will remain locked out until power...

Страница 9: ...he system shut off all electrical power to the unit Turn off accessory heater power switch if applicable Electrical shock could cause personal injury or death WARNING Periodic inspection and maintenan...

Страница 10: ...IF USED 208 230 1 60 POWER SUPPLY WITH MIN 75 C COPPER WIRE G W1 C R CONTACTOR CONTROL CIRCUIT WIRING TO BE 24 VOLT N E C CLASS 2 L1 T1 COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR DUAL CAPACITOR COMPRES...

Страница 11: ...T GRN 5 7 5KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY BLK J2 1 J2 2 BLK C 1 2 3 4 5 J2 6 J2 5 WHT BLU RED YEL WHT B1 PUR B4 BLACK ORG L N G B3 S1 TRANSFORMER TI L G N BLK K1 1 CONTACTOR YEL W STRIPE C...

Страница 12: ...pen will not be seen when Y1 is off Instead the Normal Operation or Anti Short Cycle code will be seen Also when a pressure switch opens and caused a short cycle lockout the pressure switch open code...

Страница 13: ...rt Cycle code will be seen Also when a pressure switch opens and caused a short cycle lockout the pressure switch open code will be seen until it closes then the short cycle lockout code will flash un...