Improper  installation,  adjustment,  alteration,  service, 

or maintenance can cause injury or property damage. 

Refer to this manual. For assistance or additional 

information,  consult  a  qualified  installer  or  service 

agency.

WARNING

Installation

These instructions explain the recommended method of 

installation of the packaged heat pump and air conditioner 

units and associated electrical wiring.

This  unit  is  designed  and  approved  for  use  as  a  self-

contained air-to-air outdoor heat pump and air conditioner 

system.

The  units  are  factory-equipped  with  a  transformer  and 

blower  control  for  applications  without  auxiliary  heat. 

Electric heat accessory kits (PHK-) can be ordered for field 

installation of additional heat where required.

These  instructions,  and  any  instructions  packaged  with 

mating components and/or accessories, should be carefully 

read prior to beginning installation. Note particularly any 

CAUTIONS

 or 

WARNINGS

 in these instructions and all 

labels on the units.

These instructions are intended as a general guide only, 

for use by qualified personnel and do not supersede any 

national or local codes in any way. Compliance with all local, 

state, provincial, or national codes pertaining to this type of 

equipment should be determined prior to installation.

Inspection of Shipment

Upon receipt of equipment, carefully inspect it for possible 

shipping damage. If damage is found, it should be noted 

on the carrier’s freight bill. Take special care to examine 

the unit inside the carton if the carton is damaged. File a 

claim with the transportation company.

If any damages are discovered and reported to the carrier, 

DO NOT INSTALL THE UNIT, 

as claim may be denied

.

Check  the  unit rating  plate  to  confirm  specifications 

are as ordered.

Limitations

The unit should be installed in accordance with all national 

and local safety codes.

Limitations of the unit and appropriate accessories must 

also be observed.

The  unit  must  not  be  installed  with  any  ductwork  in  the 

outdoor air stream. The outdoor fan is not designed to 

operate against any additional static pressure.

Location

The unit is designed to be located outdoors with sufficient 

clearance for free entrance to the air inlet and discharge 

air  openings.  The  location  must  also  allow  for  adequate 

service access. 

The unit must be installed on a solid foundation that will 

not settle or shift. Adequate structural support must be 

provided. Install the unit in level position. Isolate the base 

from the building structure to avoid possible transmission 

of sound or vibration into the conditioned space.

The heat pump unit foundation should be raised to a 

minimum of 3” above finish grade.

 In areas that have 

prolonged  periods  of  temperature  below  freezing  and 

snowfall, the heat pump unit should be elevated above the 

average  snow  line.  Extra  precaution  should  be  taken  to 

allow free drainage of condensate from defrost cycles to 

prevent ice accumulation. The unit should not be located 

near  walkways  to  prevent  possible  icing  of  surface  from 

defrost condensate.

Avoid placing the unit near quiet areas, such as 

sleeping quarters or study rooms.

 Normal operating 

sound levels may be objectionable if the unit is placed near 

certain rooms.

For improved start-up performance, the indoor coil 

should be washed with suitable detergent to remove 

any residue from manufacturing processes. 

Roof Curb Installation

If a roof curb is used, follow the manufacturer’s Installation 

Instructions and be sure that all required clearances are 

observed. 

Rigging and Handling

Before  lifting  a  unit,  make  sure  that  the  weight  is 

distributed equally on the cables so that it will lift evenly.

CAUTION

Exercise care when moving the unit. Do not remove any 

packaging until the unit is near the place of installation. 

An optional lifting lug kit may be purchased separately for 

use in rigging the unit for lifting. Spreaders whose length 

exceeds the unit depth dimension by 6 inches MUST be 

used across the top of the unit. 

Units may also be moved or lifted with a forklift while still in 

the factory-supplied packaging. 

The lengths of the forks 

of the forklift must be a minimum of 42”.

Содержание BPHP14 Series

Страница 1: ...Code Part 1 CSA 22 1 latest edition in Canada and any state or provincial laws or local ordinances Local authorities having jurisdiction should be consulted before installation is made Such applicable...

Страница 2: ...with any ductwork in the outdoor air stream The outdoor fan is not designed to operate against any additional static pressure Location The unit is designed to be located outdoors with sufficient clea...

Страница 3: ...410A are higher than pressures in units charged with HCFC 22 All service equipment MUST be rated for use with HFC 410A refrigerant WARNING Clearances All units require certain clearances for proper o...

Страница 4: ...ed so that water or moisture cannot be drawn into the unit during normal operation CAUTION Units are factory wired for a 230 volt power supply If power supply is 208 volts it will be necessary to chan...

Страница 5: ...chments 5 Install drain pan overflow switch and wire according to downflow conversion kit instructions Filters Air filters are not supplied with the unit A field provided air filter must always be ins...

Страница 6: ...red for safety while servicing do not open the system disconnect switch Heater Kit Accessory if used The unit is fully equipped for cooling operation without auxiliary heat A heater kit accessory may...

Страница 7: ...send a signal to the defrost control board to start the defrost timing It also terminates defrost when the liquid line warms up to 60 F Figure 7 Defrost Control Board Diagnostic LEDs 24V Terminal Stri...

Страница 8: ...e control board In addition the diagnostic LEDs will indicate a locked out pressure switch after the fifth occurrence of an open pressure switch see Table 3 The unit will remain locked out until power...

Страница 9: ...he system shut off all electrical power to the unit Turn off accessory heater power switch if applicable Electrical shock could cause personal injury or death WARNING Periodic inspection and maintenan...

Страница 10: ...IF USED 208 230 1 60 POWER SUPPLY WITH MIN 75 C COPPER WIRE G W1 C R CONTACTOR CONTROL CIRCUIT WIRING TO BE 24 VOLT N E C CLASS 2 L1 T1 COMPRESSOR CONTACTOR COMPRESSOR CONTACTOR DUAL CAPACITOR COMPRES...

Страница 11: ...T GRN 5 7 5KW HEATER ACCESSORIES FUNCTION OFF W1 ONLY BLK J2 1 J2 2 BLK C 1 2 3 4 5 J2 6 J2 5 WHT BLU RED YEL WHT B1 PUR B4 BLACK ORG L N G B3 S1 TRANSFORMER TI L G N BLK K1 1 CONTACTOR YEL W STRIPE C...

Страница 12: ...pen will not be seen when Y1 is off Instead the Normal Operation or Anti Short Cycle code will be seen Also when a pressure switch opens and caused a short cycle lockout the pressure switch open code...

Страница 13: ...rt Cycle code will be seen Also when a pressure switch opens and caused a short cycle lockout the pressure switch open code will be seen until it closes then the short cycle lockout code will flash un...

Отзывы: