Ceiling Installation cont'd
• Remove the side covers and the grille.
• Bolt the threaded rod to the hanging bracket
as shown below.
Back of unit shown
Grille
Side cover
Hanging Brackets
Threaded rod
Screw nut
Washer
Hanging screw bolt
Hanging arm
Gas refrigerant line
connection
Liquid refrigerant line
connection
Drain connection
Loosen the rear mount points to achieve a
slight tilt toward the drain connection.
For best results, secure the unit through the mount points to wall studs
with lag screws. If attaching to drywall or concrete, use appropriate
anchors and test by applying side to side pressure. It is acceptable to
rest the unit on the floor, provided you still secure it to the wall.
2. Wall Mounted Installation
Indoor Unit Installation
Page 8