Blueridge BM09Y17 Скачать руководство пользователя страница 6

9

10

CARE  AND  MAINTENANCE

Care and Maintenance

OPERATING  INSTRUCTIONS

How the air conditioner works

1 hour

1 hour

Set 
Temperature

Set 
Temperature

Cooling

Heating

SLEEP  operation

1 hour 1 hour

SLEEP  operation

7 hours timer off

7 hours timer off

AUTO operation

When you set the air conditioner in AUTO mode, it will 
automatically select cooling, heating(cooling/heating 
models only), or fan only operation depending on set 
temperature and the room temperature.
The air conditioner will control room temperature 
automatically to the temperature point you set.
If you feel uncomfortable in the AUTO mode, you can set 
your desired temperature.

SLEEP operation

When you push SLEEP button on remote controller 
during cooling, heating(cooling & heating models only), 
or AUTO operation , the air conditioner will 
automatically increase (cooling) or decrease (heating)

O

O

1 C/2 F per hour for the first 2 hours, then hold 
steadily for the next 5 hours, after that it will switch off. 
This mode saves you energy and brings you comfort 
at night.

DRYING operation

Optimal operation

To achieve optimal performance, please note the 
following:
Adjust the air flow direction correctly so that it is not 
towards people.
Adjust the temperature to achieve the highest comfort 
level. Do not adjust the unit to excessive temperature 
levels.
Close doors and windows on COOL or HEAT modes, 
or performance may be reduced.
Use TIMER ON button on the remote controller to 
select a time you want to start your air conditioner.
Do not put any object near air inlet or air outlet, as the 
efficiency of the air conditioner may be reduced and 
the air conditioner may stop running.
Clean the air filter periodically, otherwise cooling or 
heating performance may be reduced.
Do not operate unit with horizontal louvre in closed 
position.

The fan speed will be automatically controlled under 
dry operation.
During the dry operation, if the room temperature is 

O

O

lower than 10 C(50 F), the compressor stops operation 
and restarts until the room temperature is above 

O

O

12 C(54 F).

Filter Handle 

O

O

1 C/2 F

O

O

1 C/2 F

O

O

1 C/2 F

O

O

1 C/2 F

Before maintenance

   A cloth  dampened with cold water may be used 
   on the indoor unit if it is very dirty.  Then wipe it 
   with a dry cloth.
   Do not use a chemically treated cloth or duster to 
   clean the unit.
   Do not use benzine, thinner, polishing powder, or
   similar solvents for cleaning. These may cause 
    the plastic surface to crack or deform.   
    Never use water hotter than 40 C/104 F to clean 
    the front panel, it could cause deformation of 
    discolouration.

CAUTIONS

Turn the system off before cleaning. To clean, wipe with
a soft, dry cloth. Do not use bleach or abrasives.

NOTE: Power supply must be disconnected before
cleaning the indoor unit.

Cleaning the unit

wipe the unit with a soft dry cloth only. If the unit is
very dirty, wipe it with a cloth soaked in warm water.

Cleaning the air filter and air freshening filter 

A clogged air filter reduces the cooling efficiency of 
this unit. Please clean the filter once every 2 weeks. 
1. Lift the indoor unit panel up to an angle until it

stops with a clicking sound. For some models,
please use suspension bars to prop up the panel.

2. Take hold of the  handle of the air filter and lift it

up slightly to take it out from the filter holder,
then pull it downwards.

3. Remove the AIR FILTER from the indoor unit.

Clean the AIR FILTER once two weeks.

       Clean the AIR FILTER with a vacuum cleaner
       or water, then dry it up in cool place.

Содержание BM09Y17

Страница 1: ...n easily find them Inside you will find many helpful hints on how to use and maintain your air conditioner properly Just a little preventative care on your part can save you a great deal of time and m...

Страница 2: ...the European countries please read the following information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lac...

Страница 3: ...the air conditioner in places where combustible gas can be emitted Emitted gas may collect and cause an explosion Never allow the air conditioner to run for too long with the doors or windows open or...

Страница 4: ...r under Cooling operation for about half an hour Once the Self Clean function is activated all TIMER setting will be cancelled During Self Clean operation when press the SELF CLEAN button on the remot...

Страница 5: ...O COOL Suspension bars AUTO COOL 1 2 Manual operation Operating temperature Manual switch Manual switch Open and lift the front panel up to an angle until it remains fixed with a clicking sound For so...

Страница 6: ...op running Clean the air filter periodically otherwise cooling or heating performance may be reduced Do not operate unit with horizontal louvre in closed position The fan speed will be automatically c...

Страница 7: ...ssor can t restart for 3 4 minutes after it stops Anti cold air Cooling and heating models only The unit is designed not to blow cold air on HEAT mode when the indoor heat exchanger is in one of the f...

Страница 8: ...ormally Trouble OPERATION indicator or other indicators continue flashing If one of the following code appears on the display area E0 E1 E2 E3 or P0 P1 P2 P3 TROUBLESHOOTING TIPS Troubleshooting guide...

Страница 9: ......

Отзывы: