507867-02
Page 4 of 55
Issue 1933
Gas Furnace
The
BG921-E
Category IV gas furnace is shipped
ready for installation in the upflow or horizontal position.
The furnace is shipped with the bottom panel in place.
The bottom panel must be removed if the unit is to be
installed in horizontal or upflow applications with bottom
return air.
The
BG921-E
can be installed as either a Direct Vent or
a Non-Direct Vent gas central furnace
The furnace is equipped for installation in natural gas
applications. A conversion kit (ordered separately)
is required for use in propane/LP gas applications.
NOTE:
In Direct Vent installations, combustion air is
taken
from outdoors and flue gases are discharged
outdoors.
In Non-Direct Vent installations, combustion
air is taken
from indoors and flue gases are
discharged outdoors. See Figure 2 and Figure 3 for
applications involving roof termination.
Figure 2.
Figure 3.
Shipping and Packing List
1 - Assembled Gas Furnace
1 - Bag assembly containing the following:
1 - Snap bushing
1 - Snap Plug
1 - Wire tie
1 - Condensate trap
1 - Condensate trap cap
1 - Condensate trap clamp
1 - 2” diameter debris screen
1 - 3/4” Threaded street elbow
Check equipment for shipping damage. If you find any
damage, immediately contact the last carrier.
Please refer to specification sheets for available
accessories
Safety Information
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
WARNING
As with any mechanical equipment, personal injury can
result from contact with sharp sheet metal edges. Be
careful when you handle this equipment.
CAUTION
DANGER OF EXPLOSION!
There are circumstances in which odorant used with
LP/Propane gas can lose its scent. In case of a leak,
LP/Propane gas will settle close to the floor and may be
difficult to smell. An LP/Propane leak detector should be
installed in all LP applications.
DANGER
Use only the type of gas approved for use with this furnace.
Refer to unit nameplate.
BG921-E
units are CSA International certified to ANSI
Z21.47 and CSA 2.3 standards.