background image

 

SeaTrac 

Upgrading Beacon Firmware 

 

 

 

2.2.

 

Programming New Firmware 

For  beacons  to  function  and  communicate  correctly,  each  SeaTrac  beacon  should  be  programmed  to  the 

firmware release using the following procedure…

 

 

 

If you 

haven’t already done so, connect the SeaTrac beacon to the serial port of a PC (or use the USB

-

to-Serial converter supplied with the SeaTrac system). 

 

Power up the SeaTrac beacon and run the 

SeaTracProgrammer

 program (either from the Start Menu, 

or by execu

ting “

SeaTracProgrammer.exe

”).

 

 

In the application window, click the drop-down list to choose the COM port the beacon is connected to 
(

), then choose a baud rate of 115200 from the second drop down list (

). Finally click “CONNECT” to 

connect to the SeaTrac beacon (

)…

 

 

 

Having  opened  the  serial  connection,  check  the  SeaTrac  Beacon  is  connected  and  get  is  hardware 

information by clicking the “INFO” button (

). 

 

If the beacon isn’t connected properly, you will see something similar to…

 

Device identifying... 
Timed out waiting for device to reply. 
Aborted. 

 

 

However, if the serial communication settings are correct, you will see information similar to…

 

Device identifying... 
Device information... 
Uptime = 4238 seconds 
Run Section = APPLICATION (1) 
Hardware Part Number = BP00795 

Hardware Revision = 6 

Hardware Serial Number = 001234 
Hardware Flags = 0x00000000 
Bootloader Valid = True 
Bootloader Part Number = BP00912 
Bootloader Version = v1.6.436 
Bootloader Checksum = 0x00000000 

 

 

 

 

Содержание Seatrac x110

Страница 1: ...UM 140 P00916 03 SeaTrac Upgrading Beacon Firmware...

Страница 2: ...UM 140 P00916 03...

Страница 3: ...ying to use beacons running different versions of the firmware may lead to unpredictable behaviour or communications failing As several versions of firmware are available for different beacon types it...

Страница 4: ...d to then choose a baud rate of 115200 from the second drop down list Finally click CONNECT to connect to the SeaTrac beacon Having opened the serial connection check the SeaTrac Beacon is connected a...

Страница 5: ...ns The larger the version number the more current the firmware release above v2 2 is never than v1 11 and so should be used pClick OPEN to choose the firmware file and close the Open File window Final...

Страница 6: ...during a previous attempt at programming or due to other circumstances Follow the Bootloader Mode procedure described below to prevent the current firmware from starting and force the Beacon to only...

Страница 7: ...n user manual for details As the magnet is moved into place the Green status LED should start quickly flashing Red to show the presence of the magnet Hold the magnet in place for 5 seconds until the s...

Страница 8: ...eriencing problems connecting the programmer software to the beacon Try reconnecting using the above setting once Bootloader mode is active and see if this resolves the issue Bootloader mode only acti...

Страница 9: ...support request Part and Serial Numbers of the system components These are located on the labels of each item and are in the form BPxxxxx xxxxxx Version numbers of any software and firmware you are us...

Страница 10: ...SeaTrac Upgrading Beacon Firmware P N BP00916 3 UM 140 P00916 03 July 2022 Distributor...

Отзывы: