background image

Minimum Temperature:

 The unit records the minimum temperature 

measured by the sensor. To reset the minimum temperature, press 

the MENU button to display the first menu item. Use the UP and 

DOWN arrow buttons to scroll through and find “Minimum Temp” on 

the LCD screen. To reset, press the ENTER button twice after the 

value is displayed.

Maximum Temperature:

 The unit records the maximum temperature 

measured by the sensor.  To reset the maximum temperature, press 

the MENU button to display the first menu item.  Use the UP and 

DOWN arrow buttons to scroll through and find “Maximum Temp” 

on the LCD screen. To reset, press the ENTER button twice after the 

value is displayed.

Control Mode: 

The unit will operate to increase or decrease the tem-

perature depending on the device connected to the unit. To change 

the Control Mode, press the MENU button to display the first menu 

item. Use the UP and DOWN arrow buttons to scroll through and find 

“Control Mode” on the LCD screen. To change the setting, press the 

ENTER button. The current setting will be highlighted to indicate the 

setting can be changed. Use the UP and DOWN arrow buttons to 

change the setting. Press the ENTER button a second time to accept 

the new setting and store it in memory.

Temperature Display:

 The unit will display the temperature in °F or 

°C. To change the Temperature Display, press the MENU button to 

display the first menu item. Use the UP and DOWN arrow buttons 

to scroll through and find “Set Temp Display” on the LCD screen. To 

change the setting, press the ENTER button. The current setting will 

be highlighted to indicate the setting can be changed. Use the UP and 

DOWN arrow buttons to change the setting. Press the ENTER button 

a second time to accept the new setting and store it in memory.

Troubleshooting

The LCD screen is blinking and showing an error 

message.

 

All detected errors will cause the unit to go into “safe mode.” It will shut 

down the connected device and display one of the following errors:

Temp Sensor

 (problem with sensor)

Overload 

(current draw exceeds 10A)

Holding the ENTER button for 3 seconds will reset any error except 

for OVERLOAD. In this case, disconnect the unit from the electrical 

supply to reset the error. It may be necessary to reduce the size of the 

connected equipment (if it exceeds a 10A draw) to prevent the OVER-

LOAD error from reoccurring.

See warranty procedure information if you reset the unit and the error 

code continues to appear.

How can I calibrate the temperature sensor?

 

The sensor does not require any calibration.

The unit is turning on and off at the wrong temperatures. 

Make sure you have selected the correct control mode for the device 

connected to the unit.

Limited 3-Year Warranty Terms

Sunleaves Garden Products warrants that the Blueprint Digital Day/Night Temperature Controller will remain free from 

appearance of defects in workmanship and materials for 3 years from date of original retail purchase. This warranty is 

subject to the following limitations: (a) manufacturer’s liability is limited to the replacement or repair of the unit, as decided 

by the manufacturer; (b) a defective unit must be returned, prepaid, with proof of purchase to the point of purchase or as 

instructed below; and (c) this warranty does not apply to defects resulting from the alteration, abuse, accidental damage, 

unauthorized repair or misuse of the unit. This warranty is given in lieu of all other warranties, guarantees and conditions 

on manufacturer’s part, and the manufacturer shall have no tortious or other liability in respect to this Blueprint Digital 

Day/Night Temperature Controller.

Blueprint Digital Day/Night Temperature Controller Warranty Is Void If:

• NOT ACCOMPANIED BY THE ORIGINAL PROOF OF PURCHASE.

• BLUEPRINT DIGITAL DAY/NIGHT TEMPERATURE CONTROLLER HAS BEEN USED IN A NONSTANDARD WAY, INCLUDING GENERAL MISUSE  

  AND OUTDOOR USE.

• BLUEPRINT DIGITAL DAY/NIGHT TEMPERATURE CONTROLLER HAS BEEN DAMAGED AS A RESULT OF ACCIDENT, IMPROPER    

 

  INSTALLATION, ALTERATION, OR FIRE, FLOOD OR OTHER NATURAL DISASTER.

Blueprint 3-Year Limited Warranty

All Blueprint Digital Day/Night Temperature Controllers are protected against manufacturer defect by a limited 

3-year manufacturer’s warranty.

Sunleaves Product Warranty Claims

To obtain warranty service in the event that your product fails to operate, return the product to the place of purchase. Often the retailer will be able 
to examine the product in closer detail, determine the problem and even fix the product on site.

For technical support and warranty information, call our toll-free number at 888-464-9676 

or email: [email protected].

7854 North State Road 37

Bloomington, IN 47404

rev:112013

Отзывы: