Features of your Blueprint Digital Day/Night 

Temperature Controller, BDTC-1

• Precisely control a 120V cooling or heating device

• Integrated photocell allows day, night or 24-hour operation

• Remote sensor on a 6.5’ cable accurately monitors temperature

• Stores minimum and maximum temperature values

• Wall mountable

• 3-year warranty

Specifications

Input Voltage: 120V

Maximum Amperage: 14.5A @ 120V

Temperature Control Range: 32-150ºF

Separate Day and Night Settings: Photocell Control

Temperature Deadband: 1 - 10ºF

Dimensions: 3” x 6” x 3.5”

Equipment Power 

Connection

Wall Mount Access

LCD Screen

Menu Button

LED Indicator 

Enter Button

Photocell
Up Button

Down Button

Temperature Sensor

Thank you for choosing to grow with Blueprint 

Controllers! Your satisfaction and success are 

important to us. For best results, carefully read the 

following instructions before using your Blueprint 

Digital Day/Night Temperature Controller.

Installation

1.  Connect the unit to a 120V power source.

2.  If desired, mount the unit to the wall or alternate support 

  using the mounting tab.

3.  Program desired settings.

4.  Position remote sensor in best location to accurately gauge   

  environmental temperatures for proper unit functioning.

5.  Connect the device to be controlled.

    

    

Ensure the device being connected to the  

   

 

Controller has the proper voltage and will  

   

 

not exceed the maximum amperage rating  

   

 

of the unit.

    

Do not expose the unit to water.

Factory Settings

•  Day Temperature: 78.0ºF

•  Night Temperature: 75.0ºF

•  Temperature Deadband: 2.0ºF

•  Control Mode: Cooling

•  Temperature Display: F

Restoring Factory Settings

Factory settings can be reinstated at any time by pressing and holding 

the MENU and UP buttons for 3 seconds, then pressing ENTER. This 

will reset all settings except for the Temperature Display (will not return 

to ºF if it has been set to ºC).

LCD Screen

Selecting Controller Settings

Day Temperature:

 To set the temperature the unit will use to 

control the output when the photocell determines it is daytime, 

press the MENU button. Use the UP and DOWN arrow buttons 

to scroll through and find “Set Day Temp” on the LCD screen. To 

change the setting, press the ENTER button. The current setting 

will be highlighted to indicate the setting can be changed.  Use 

the UP and DOWN buttons to change the setting. Press the 

ENTER button a second time to accept the new setting and store 

it in memory.

Night Temperature:

 To set the temperature the unit will use to 

control the output when the photocell determines it is nighttime, 

press the MENU button.  Use the UP and DOWN arrow buttons 

to scroll through and find “Set Night Temp” on the LCD screen.  

To change the setting, press the ENTER button.  The current 

setting will be highlighted to indicate the setting can be changed.  

Use the UP and DOWN buttons to change the setting.  Press the 

ENTER button a second time to accept the new setting and store 

it in memory.

Temperature Deadband:

 To change the temperature deadband, 

press the MENU button to display the first menu item.  Use the 

UP and DOWN arrow buttons to scroll through and find “Set 

Deadband” on the LCD screen.  To change the setting, press the 

ENTER button. The current setting will be highlighted to indicate 

the setting can be changed.  Use the UP and DOWN arrow but-

tons to change the setting.  Press the ENTER button a second 

time to accept the new setting and store it in memory.

Caution

Warning

Photocell Status

Current Temperature

Control Status