Installation

• Mount the Controller on the wall. Place the remote sensor at plant    

  height in an area with good air circulation. Avoid placing the sensor in  

  a location with direct, intense exposure to light.

• Connect the sensor cable to the bottom of the unit using the 

  quick-disconnect screw.

• Plug the Controller into a 120V NEMA 5-15 wall outlet.

• Turn the power on and allow the unit to warm up for 5 minutes.

  While the unit is warming up, the display will read “CO

2

 heat.”

• Program the desired settings before connecting any devices.  

 

•  Plug the devices to be controlled by the unit into the 

  receptacles on the unit’s sides. 

   

 

• Ensure the devices being connected to the

   

 

  Controller have the proper voltage and will

   

 

  not exceed the maximum amperage rating

   

 

  of the unit.

   

 

• Before using a sulfur vaporizer around the

   

 

  Controller, remove the remote sensor

   

 

  from the affected area or turn the unit off

   

 

  and cover the sensor with a protective

   

 

  plastic bag. Remove the bag before turning

   

 

  the Controller back on. Note: Failure to

   

 

  protect the remote sensor during sulfur use

   

 

  will result in damage to the infrared CO

2

   

 

  sensor and void the warranty.

   

 

• Do not expose the unit to water.

Factory Settings

The Controller is preprogrammed with the following 

factory settings:

• Temperature Day Setting: Cooling – 80°F / heating – 55°F

• Temperature Night Setting: Cooling – 70°F / heating – 55°F

• Temperature Deadband: 3°F cooling and heating

• Humidity Setting: 50% RH

• Humidity Mode: Decrease

• Humidity Deadband: 5%

• CO

2

 Level: 1250 ppm

• CO

2

 Deadband: 50 ppm

• CO

2

 Calibration: 380 ppm

• Temperature/Humidity Lock: Split

• Temperature/CO

2

 Lock: Split

Restoring Factory Settings:

 Hold the “Enter/Reset” and DOWN 

arrow buttons for 3 seconds. The display will read “f.Set.” Press the 

“Enter/Reset” button again to restore the default factory settings. When 

the process is complete, the display will read “donE.” Note: It may take 

up to 15 seconds to complete the process.

Error LEDs

When the Controller is functioning normally, the ambient CO

2

 level, 

temperature and humidity will change slowly but steadily. If the 

Controller does not detect a change in CO

2

 level, temperature or 

humidity within a 1-hour period, the unit will deactivate the affected 

output and the corresponding green error LED will flash to indicate 

which device may be malfunctioning. Ensure the device and remote 

sensor are functioning properly. To reset the error, press the 

“Enter/Reset” button.

Adjusting Photocell Sensitivity

• To change the photocell’s sensitivity, hold the DOWN arrow  

  button for 3 seconds. The current setting will be displayed.

• Press the UP arrow button to increase the number displayed, 

  decreasing the amount of light required to activate the photocell.

• Press the DOWN arrow button to decrease the number displayed,    

  increasing the amount of light required to activate the photocell.

• Press “Enter/Reset” to accept the new setting.

Selecting Temperature Settings

Temperature Display:

 Hold the UP and DOWN arrow 

buttons for 3 seconds to change the temperature display from 

Fahrenheit to Celsius.

Temperature Day: 

The Controller allows day cooling and day 

heating set-points. To set the temperature at which the cooling 

output will be activated during the day, press the “Day Setting” 

button. The display will read “CooL__F.” Use the UP and DOWN 

arrow buttons to adjust the setting. Press “Enter/Reset” to accept 

the new setting. To set the temperature at which the heating output 

will be activated during the day, press the “Day Setting” button twice. 

The display will read “HEAt__F.” Use the UP and DOWN arrow 

buttons to adjust the setting. Press “Enter/Reset” to accept the 

new setting.

Temperature Night:

 The Controller allows night cooling and 

night heating set-points. To set the temperature at which the cooling 

output will be activated at night, press the “Night Setting” button. The 

display will read “d.CooL__F.” Use the UP and DOWN arrow buttons 

to adjust the setting. Press “Enter/Reset” to accept the new setting. 

To set the temperature at which the heating output will be activated 

at night, press the “Night Setting” button twice. The display will read 

“HEAt__F.” Use the UP and DOWN arrow buttons to adjust the set-

ting. Press “Enter/Reset” to accept the new setting.

Temperature Deadband:

 The Controller allows cooling and 

heating deadband settings. To set the cooling deadband, press the 

“Deadband” button under “Temp.” The display will read “d.CooL__F.” 

Use the UP and DOWN arrow buttons to adjust the setting. Press 

“Enter/Reset” to accept the new setting. To set the heating dead-

band, press the “Deadband” button twice under “Temp.” The display 

will read “d.HEAt__F.” Use the UP and DOWN arrow buttons to 

adjust the setting. Press “Enter/Reset” to accept the new setting.

Note:

 To prevent the unit from activating both the cooling and 

heating devices at the same time, the difference between the heating 

and cooling set-points must be greater than the combined deadband 

set-points.

Selecting Humidity Settings

Humidity Day:

 To select the humidity level at which the humidity 

output will be activated during the day, press the “Day/Night Setting” 

button. The display will read “dAy_rH.” Use the UP and DOWN arrow 

buttons to adjust the setting. Press “Enter/Reset” to accept the 

new setting.

Humidity Night:

 To select the humidity level at which the humidity 

output will be activated at night, press the “Day/Night Setting” button 

twice. The display will read “nit_rH.” Use the UP and DOWN arrow 

buttons to adjust the setting. Press “Enter/Reset” to accept the 

new setting.

Humidity Mode:

 To select between humidifying and 

dehumidifying modes, press the “Humidify/Dehumidify” button.

The display will show the current setting, “rh_Incr” for humidifying 

and “rh_dEcr” for dehumidifying. Use the UP and DOWN arrow but-

tons to choose between modes. Press “Enter/Reset” to accept the 

new setting. 

Humidity Deadband:

 To set the humidity deadband, press the 

“Deadband” button under “Humidity.” The display will show the 

current setting. Use the UP and DOWN arrow buttons to 

adjust the setting. Press “Enter/Reset” to accept the new setting.