SJT-WVF-V
Elevator Group Control User Manual
Shenyang Bluelight
Page 12
Ver. 2007
2.10.7
Set Homing Floor
This function is available for software version 706_12 and higher versions.
When the elevator group is idle (no car and hall calls for 5 minutes), if the Homing Floor is set to “0” for every
elevator in the group control system, the group control system will automatically distribute the elevators to
average region based on number of floor; for example, if there is a 20 floors building having 3-car Group control
system, Elevator-A will be distributed to Floor 01 for waiting call, Elevator-B will be distributed to Floor 06 for
waiting call and Elevator-C will be distributed to Floor 12 for waiting call.
General Para
Enter
A: Homing Floor
Enter
Enter
Esc
B: Homing Floor
Enter
C: Homing Floor
Enter
H: Homing Floor
Enter
A: Stop Floor
Enter
A: Stop Floor
01: ON / OFF
Enter
Esc
A: Stop Floor
02: ON / OFF
A: Stop Floor
03: ON / OFF
A: Stop Floor
64: ON / OFF