48
Shenyang Bluelight Automatic Technology Co., Ltd.
BL6-DU20PX series Integrated Door Motor Controller User Manual
7.2.2
Distance Control Mode
A. As an all-purpose door motor controller, pulse and limit switch mode application wiring
diagram.
COM
DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI 7
DI 8
Door-open slowdown signal
Door-open limit signal
Door-close slowdown signal
Door-close limit signal
Door-open instruction signal
Door-close instruction signal
Standby signal
Standby signal
1-phase Power Supply
L1
L2
PE
TA2
TB2
TC2
TA3
TB3
TA1
TB1
TC1
Elevator
Control
System
Arrival to close limit output
Arrival to open limit output
Control system input com
Control system input com
M
U
V
W
En
co
de
r
24V
PGA
PGB
PGZ
COM
F
IGURE
7.4
D
ISTANCE CONTROL MODE
(
PULSE
+
LIMIT SWITCH
)
APPLICATION WIRING DIAGRAM
In this work mode, if the limit switch is valid, the arrival to open or close limit output is valid,
and not dependent on pulses. Using limit signal should be set in input terminal type.
B. As an all-purpose door motor controller, all-pulse mode application wiring diagram
COM
DI 1
DI 2
DI 3
DI 4
DI 5
DI 6
DI 7
DI 8
Standby signal
Standby signal
Standby signal
Standby signal
Door-open instruction signal
Door-close instruction signal
Standby signal
Standby signal
1-phase Power Supply
L1
L2
PE
TA2
TB2
TC2
TA3
TB3
TA1
TB1
TC1
Elevator
Control
System
Arrival to close limit output
Arrival to open limit output
Control system input com
Control system input com
M
U
V
W
En
co
de
r
24V
PGA
PGB
PGZ
COM
F
IGURE
7.5
F
ULL
-
PULSES MODE APPLICATION WIRING DIAGRAM
Note: In this work mode, all switch signals are produced by pulse counter, and no limit signal
should be set in input terminal type.