TROUBLESHOOTING
When ignitor button is
pressed in there is a
spark at ODS/pilot but
no ignition.
1. Gas supply is turned off or
equipment shutoff valve is
closed.
2. Control knob not fully
pressed in while pressing
ignitor button.
3. Air in gas lines when
installed.
4. ODS / pilot is clogged.
5. Incorrect inlet gas pressure
or inlet regulator is
damaged.
6. Control knob not in PILOT
position.
7. Depleted gas supply
(propane).
1. Turn on gas supply or open
equipment shutoff valve.
2. Fully press in control knob
while pressing ignitor button.
3. Continue
holding
down
control knob. Repeat igniting
operation
until
air
is
removed.
4. Clean ODS/pilot (see
Care
and Maintenance
, page 20)
or
replace
ODS/pilot
assembly.
5. Check inlet gas pressure or
replace inlet gas regulator.
6. Turn control knob to PILOT
position.
7. Contact local propane/LP
gas company.
Problem
Possible Cause
Corrective Action
ODS/pilot
lights
but
flame goes out when
control knob is released.
1. Control knob is not fully
pressed in.
2. Control knob is not pressed
in long enough.
3. Equipment shutoff valve is
not fully open.
4. Thermocouple connection is
loose at control valve.
5. Pilot flame not touching
thermocouple, which allows
thermocouple
to
cool,
causing pilot flame to go out.
This
problem
could
be
caused by one or both of the
following:
A) Low gas pressure
B) Dirty or partially clogged
ODS/pilot
6. Thermocouple damaged.
7. Control valve damaged.
1. Press in control knob fully.
2. After ODS/pilot lights, keep
control knob pressed in 30
seconds.
3. Fully open equipment
shutoff valve.
4. Hand tighten until snug, and
then tighten 1/4 turn more.
5. A) Contact local natural or
propane/LP gas company
B) Clean ODS/pilot (see
Care
and Maintenance
, page 20)
or
replace
ODS/pilot
assembly
6. Replace thermocouple.
7. Replace control valve.
Burner(s) does not light
after ODS/pilot is lit.
1. Burner orifice is clogged.
2. Inlet gas pressure is too
low.
1. Clean burner orifice (see
Care and Maintenance
,
page 20).
2. Contact local gas supplier.
Содержание B10TNIR-B
Страница 5: ...2000458 01A www bluegrassliving com 5 SAFETY ...
Страница 36: ...36 www bluegrassliving com 200458 01A PARTS MODELS B10TNIR B B10TPIR B ...
Страница 37: ...2000458 01A www bluegrassliving com 37 PARTS ...
Страница 41: ... 2000458 01A www bluegrassliving com 41 PARTS ...
Страница 49: ...2000458 01A www bluegrassliving com 49 1 866 762 4050 08 19 ...