STEP 1:
Place top plate with the front face
on clean and smooth working area,
to prevent scratches. Then place
housing on, as it is shown in the
figure on the left. Beware to match
the part with logo on housing and
indentation on top plate.
STEP 2:
Fit the sealing ring in the outside
channel with matching size. The
rounded part of sealing ring should
be facing upward. Then align the
jet-plate as it is shown in the figure
on the left (long side of a gap in top
plate must be aligned to long side of
a gap in jet-plate, for more, see:
Important tip
at the bottom of the
page).
STEP 3:
Place coldplate with the fins
perpendicular to long side of a gap
in jet-plate. Then use the four M4
screws to secure the whole water-
block together. DO NOT use
extensive force, or you may
damage the threads or top plate
itself.
Important tip:
Proper jet-plate and
coldplate alignment.