BLUEBOX Advant UHF
Page 23 of 102
3
Operating Features
In ‘continuous’ mode the
BLUEBOX
is characterized by the coexistence of 2
‘parallel’ and asynchronous activities: the tag identification (inventory) and the
communication with the ‘host’ system. The ‘continuous’ identification acti
vity
interacts with the communication activity through a buffer that contains the code
of the last identified tags or that is empty indicating the absence of tags. Due to
synchronization and filtering reasons, the buffer is handled for each identified
tag
by a parameter defined as ‘hold time’ (same as ‘filter time’ defined below,
to be set in the range of 0 … 99 seconds or 0 ... 99 minutes, default value 1
second) and allows to extend ‘artificially’ the presence of the tag after it leaves
the antenna’s infl
uence area; this behavior is observable looking at the yellow
led status that is ‘on’ indicating the presence of tags and also through the
activation of the relay nr 1 (if its ‘automatic’ management is enabled by the flag
defined in the general parameters
). Through the command ‘data request’ it is
possible to get the data contained in the buffer (tag/s ID/s and optionally tag/s
type/s, reading antenna and gate crossing direction in ‘gate mode’); the
indication of the reading antenna can be enabled/disabled through a flag defined
in the general parameters.
The
BLUEBOX
handles also a 1000 elements FIFO queue which is combined with
the ‘filter time’ general parameter (to be set in a range of 0 … 99 seconds or 0
... 99 minutes, default value 1 second) that prevents the queue saturation in
case of a tag ‘continuous’ presence. When a tag is identified, the
BLUEBOX
verifies if it belongs to the list of read tags. If the tag do not belong to the list
(it is defined as ‘new’), its code will be inserted in the queue,
a filter time
assigned to the tag will be started and the buzzer will be activated for 0.5
seconds (if its ‘automatic’ management is enabled by the flag defined in the
general parameters). Otherwise (the tag belong to the list of read tags), the
BLUEBOX
verifies if the relative filter time is expired. In this case (the filter time
is expired), the tag is defined as ‘new’ and will be processed as described above,
otherwise only the relative filter time will be rearmed. Through the command
‘queue data request’ and the relative ‘ack’, it is possible to get the data contained
in the queue (tag ID and optionally tag type, reading antenna and gate crossing
direction in ‘gate mode’) and unload it; the indication of the reading antenna can
be enabled/disabled through a flag defined in the general parameters.
In ‘continuous’ mode the
BLUEBOX
can be configured to obtain the behavior of
a ‘spontaneous’ reader that will send a message on the RS232 serial line and
Ethernet line. This feature is enabled (on) / disabled (off) using a flag in the
general configuration of the reader
Two subsets of the ‘continuous’ mode are also defined:
•
‘Trigger’ mode: the activation and deactivation of the ‘continuous’ mode is
triggered with inputs. The trigger could be level sensitive or edge sensitive
Содержание IDTRONIC GEN2 ADVANT UHF
Страница 22: ...BLUEBOX Advant UHF Page 22 of 102 Standard Single Tag 15ms 20ms...
Страница 75: ...BLUEBOX Advant UHF Page 75 of 102 7 Mechanical Drawings 5221U 5221U S 5237U 5237U S...
Страница 76: ...BLUEBOX Advant UHF Page 76 of 102 5231U 5222U 5222U S...
Страница 77: ...BLUEBOX Advant UHF Page 77 of 102 5238U 5238U S 5232U...
Страница 78: ...BLUEBOX Advant UHF Page 78 of 102 5223U 5223U S 5239U 5239U S...
Страница 79: ...BLUEBOX Advant UHF Page 79 of 102 5233U 5222U MB S...
Страница 80: ...BLUEBOX Advant UHF Page 80 of 102 5238U MB S 5232U MB Alle dimensions in mm...
Страница 98: ...BLUEBOX Advant UHF Page 98 of 102 Module 64 Words Out 0x80 0xFF 40 EndModule...
Страница 100: ...BLUEBOX Advant UHF Page 100 of 102 5 On the next screen choose Advanced Options 6 Then click on Startup Settings...