![BlueBOLT BB-RS232 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/bluebolt/bb-rs232/bb-rs232_quick-start-manual_2777375002.webp)
NOTE: This equipment has been tested and
found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide rea-
sonable protection against harmful interference
in a residential installation. This equipment gen-
erates, uses and can radiate radio frequency
energy and, if not installed and used in accor-
dance with the instructions, may cause harmful
interference to radio communications. However,
there is no guarantee that interference will not
occur in a particular installation.
FOR MORE INFORMATION
FCC CLASS B DIGITAL DEVICE
www.furmancontractor.com
or
www.mybluebolt.com
Or call:
877-486-4738
or
800-472-5555
FEATURES
COMMUNICATION PORTS
RS-232 with DSUB 9 Male connector. Pins
2 (RXD), 3 (TXD) and 5 (COM) are used for
communication, pins 1 (GND) and 9 (+12V)
are used for power.
100BaseT Ethernet Communication with
BlueBOLT service or a control system on
the Local Area Network.
INDICATORS
For BlueBOLT connected, Status, Ethernet
Link Status, and Data Activity.
RESET BUTTON
Short press of Reset causes adaptor to re-
set the device. Holding down Reset for >10
seconds causes adaptor to revert to its de-
fault setting.
POWER
Powered through non-communication sig-
nal wires of supplied 9-conductor cable (for
RS232 port) or with included wide-range
AC/DC switched-mode wall adaptor.
BB-RS232 can be mounted on the rear rack
rails using included rack screws (2).
BB-RS232 can also be zip-tied (zip-ties not
included) to the inside of the equipment
rack or mounted to the wall utilizing its
flange holes. The Adaptor may also be situ-
ated on the floor, provided there is no risk of
the product being damaged.
NOTE:
That the placement of the Adaptor
should take into consideration the proximity
of the BlueBOLT-enabled product it is con-
nected to. The supplied 9-conductor cable
is 3 feet. Additionally, the AC Wall adaptor
cord length is 6 ft. (if needed).
It is recommended that you read the entire
list of instructions before proceeding.
ATTENTION: PLEASE RETAIN MAC AD-
DRESS IDENTIFICATION NUMBER AND
CHALLENGE KEY. This is unique to every
BB-RS232 adapter and will be required
for registration. Connect an Ethernet cable
(sold separately) between the BB-RS232
and an Internet router or
modem with an
established Internet connection.
Q.
Is your BB-RS232 receiving power?
A.
Check the Status LED and confirm the
unit is on.
Q.
Is your Internet connection functioning?
A.
The “Link” light should be illuminated
(solid green) and the “Activity” light should
be blinking intermittently (green).
Q.
Is your BB-RS232 connected to your in-
ternet router or modem?
A.
Check the Ethernet cable and confirm
that the unit is connected to an active Inter-
net connection, and make sure those con-
nected devices are receiving power.
If you have answered “Yes” to all of these
questions and are still unable to connect
your Power Management component, con-
tact Panamax/Furman customer service at
1-877-486-4738.
The BB-RS232 uses a Male 9-Pin DE9
(D-Sub) connector for power and serial
communications. A BlueBOLT
®
enabled
host device will have the opposite gender
(Female) of the same type of 9-Pin DE9
connector. To connect the BB-RS232 to a
BlueBOLT™ enabled device, use the DE9
Male to Female cable supplied with BB-
RS232.
The table below shows the pin and signal
designations for the DE9 connector on the
BB-RS232.
5 4 3 2 1
6 7 8 9
ACCESSORY POWER ONLY
(12VDC RETURN)
RECEIVE DATA
TRANSMIT DATA
ACCESSORY ACTIVE SIGNAL
SIGNAL GROUND
NO CONNECTION
REQUEST TO SEND
CLEAR TO SEND
ACCESSORY POWER ONLY
(POSITIVE 12V)
PIN NO.
1
2
3
4
5
6
7
8
9
ACCESSORY POWER ONLY
RECEIVE DATA
TRANSMIT DATA
ACCESSORY POWER ONLY
SIGNAL GROUND
ACCESSORY POWER ONLY
REQUEST TO SEND
CLEAR TO SEND
ACCESSORY POWER ONLY
LOCATION AND MOUNTING
INSTALLATION
Ethernet Link
(On=Link Active, Green)
Ethernet Data Activity
(Blinking=Data Activity, Green)
Ready
(On=Unit Booted
Up, Green)
BlueBOLT Connected
Indicator
Push Button
to Reset
AC/DC Adaptor
Receptacle
Ethernet
(100BaseT,
RJ-45 Jack)
RS-232 (DTE pinout, DE-9)
ACTIVITY LINK
PUSH TO
RESET
STATUS
BlueBOLT
POWER
ETHERNET
+12VDC IN 400mA
CONNECT ONL
Y TO
BlueBOLT SUPPOR
TED
DEVICES WITH
9-CONDUCTOR
STRAIGHT-THROUGH
CABLE !
CONNECT ONLY TO
BlueBOLT SUPPORTED
DEVICES WITH
9-CONDUCTOR
STRAIGHT-THROUGH
CABLE !
BlueBOLT REGISTRATION
DE-9 - PIN CONNECTOR
TROUBLESHOOTING
DQS-00015-B
• Pour le document Français, veuillez contacter:
• Para ponerse en contacto con el documento Español:
• Für deutsche Dokument Kontakt:
•
Для российского документа обращайтесь:
www.furmancontractor.com
or
www.mybluebolt.com
BB-RS232 again. If you are still unsuccess-
ful, confirm that the Ethernet connection
to the BB-RS232 is working. If you need
further assistance please call our technical
support at the following number: 877-486-
4738 or 800-472-5555.
Your BB-RS232 is BlueBOLT
®
enabled and
can be accessed from anywhere in the world
using your favorite internet browser, such as
Internet Explorer, Firefox, or Chrome.
To access you BB-RS232 you will need to
go to: www.mybluebolt.com and create a
BlueBOLT
®
user account using the “Create
an Account” button
Once you have setup a BlueBOLT
®
account,
you can log in and use the “Add a Location”
button to add a new location.
Once you have added a new location, you
can click on the name of the location and
then add your BB-RS232 device by clicking
on the “Add Device” button.
After you click on the “Add Device” button, a
screen will appear and you will be asked to
fill in the MAC ID number from your device’s
label. The label appears on the underside of
the BB-RS232.
After entering the information from your BB-
RS232, click on the “Register Now” button
and our BlueBOLT
®
servers will attempt to
find your BB-RS232. This should take less
than a minute.
If your BB-RS232 is not found within five
minutes, check and re-enter the device
information and attempt to register your
CONNECT ONL
Y TO
BlueBOLT SUPPOR
TED
DEVICES WITH
9-CONDUCTOR
STRAIGHT-THROUGH
CABLE !
CONNECT ONLY TO
BlueBOLT SUPPORTED
DEVICES WITH
9-CONDUCTOR
STRAIGHT-THROUGH
CABLE !
1 2 3 4 5
6 7 8 9
® 2014 Core Brands LLC. All rights reserved. BlueBOLT, Furman and Panamax are registered trademarks of Core Brands LLC, a company of Nortek, Inc.