! Read these instructions. ! Failure to follow maintenance guidelines may result in a cancellation of warranty 

Содержание BLMT Series

Страница 1: ...al www blueairfse com Reach Ins Stainless Steel BSR HC BSF HC BSR T HC BSF T HC 23 49 72 23T 49T 72T Food Prep Tables Undercounters BLUR HC BLUF HC BLPT HC BLMT HC 28 36 48 60 72 and optional Drawer models Work top models Read these instructions Failure to follow maintenance guidelines may result in a cancellation of warranty ...

Страница 2: ...anual owner s guide before attempting to service this product All safety precautions must be followed Caution Risk of fire or explosion Dispose of properly in accordance with federal or local regulations Flammable refrigerant used Caution Risk of fire or explosion due to puncture of refrigerant tubing follow handling instructions carefully Flammable refrigerant used Caution Keep clear of obstructi...

Страница 3: ...ation location should not be exposed to direct sunlight and not placed near any heat source e g stove oven radiator or etc Replacement of parts Component parts must be replaced with like components Servicing shall be done by authorized service personnel to minimize the risk of possible ignition due to incorrect parts or improper service Lamps must be replaced by identical lamps only If the supply ...

Страница 4: ...34F 200 4 R835A 150 1set 26ea R834G 120 1set 6ea BLPT BLMT72 HC R834F 200 4 R835A 150 1set 26ea R834G 120 1set 6ea BLUR BLPT BLMT 28 D2 HC R834F 200 4 n a n a BLUR BLPT BLMT 48 D4 HC R834F 200 4 n a n a BLUR BLPT BLMT 60 D4 HC R834F 200 4 n a n a BLUR BLPT BLMT 72 D6 HC R834F 200 4 n a n a 2 Installation Before you start to install your Blue Air unit carefully inspect it for freight damage If dama...

Страница 5: ...or unit with casters Models Four shims have been provided in the caster package for leveling unit with casters units positioned on uneven floors Shims must be positioned between rail end and bearing race If the cabinet is not level use a 3 4 19mm open end wrench to turn the anchoring bolt under the bearing race counter clockwise until the cabinet is level Install the desired number of shims making...

Страница 6: ...its length or at either end Plugs used depending on unit 1 NEMA Plugs NEMA 5 15R 115V 60 1 2 Make sure the power cord is connected to the proper voltage Rated 10 3 Compressor warranties are void if compressor burns out due to usage of improper voltage 4 A protected circuit of the correct voltage and amperage must be used 5 Turn off the power switch before disconnecting the power cord whenever perf...

Страница 7: ...36 48 60 72 HC Hold 33F 38F 0 5 3 3 BLMT28 36 48 60 72 HC Hold 33F 38F 0 5 3 3 BLUF28 36 48 60 HC Hold 10F 23 3 2 Operations Connect the power to the unit the display panel will light up and the compressor will begin to run The compressor is automatically cycled by the electronic controller The interior light is activated by the door switch when the door is open applies only to reach in models Eva...

Страница 8: ...e company Tools Required Screwdriver and Vacuum cleaner N2 or CO2 Tank Stiff bristle Brush Cleaning the condenser coil 1 Table units Disconnect power to unit Take off rear cover at the bottom rear by removing screws only rear table unit Do not bend or pinch tubes and wires Clean off accumulated dirt from condensing coil and fan blades with a stiff bristle brush Vacuum dirt from the condenser coil ...

Страница 9: ...ning your stainless steel products that make sure to use non abrasive Cleaning along stainless steel finish line s Always scrub parallel to visible lines on stainless steels Use a plastic scouring pad or soft cloth when you cannot see the grain Use the cleaners that are either Alkaline Alkaline chlorinated or Non Chloride based Avoid cleaners containing quaternary salts as they can attack stainles...

Страница 10: ...o high Correct temperature set point The door is opened too frequently Minimize door opening Loading of too much warm or moist product Load product in intervals Not enough ventilation Move the unit to a well Ventilated location with at least 3 Inches of clearance on all sides Condenser is clogged Clean it Condensation On cabinet exterior High moisture air can produce dews during the rainy season W...

Страница 11: ...m Blue Air has a Nationwide Service Network to provide timely services to our customer s needs Please call or fax us at the following numbers Toll Free 1 866 677 8500 Blue Air Refrigeration Nationwide Service Network TEL 310 808 0102 Fax 310 808 0242 0262 ...