P-1 / Set evaporator temperature for harvest control: Once evaporator sensor
reaches the
set temperature, harvest cycle will be done. [Default Setting : 7℃
(44.6
℉
)]
-
P-2 / Set harvest delay time
-
HI: Set harvest delay time after evaporator sensor reaches a set
temperature[
Default : 7℃
(44.6
℉
)] use this adjustment when ambient
temperature is high.
-
LO: Set harvest delay time after evaporator sensor reaches a set
temperature[
Default : 7℃
(44.6
℉
)] use this adjustment when ambient
temperature is low.
P-3 / Set drainage cycle interval : Set drainage cycle interval to drain remaining
water at the bottom of water tank. [Default: Every 10 freezing cycles]
-
P-4 / Sensor temperature correction: Set the correct temperature range if there is a
temperature discrepancy between sensor and actual thermometer. [Default : 0 ]
-
P-5 / Set water pump delay time to prevent ice from turning to slush. Set the
pump motor to stop when the evaporator sensor reads the set temperature. This
will prevent the ice from turning to slush. [Default : 15 seconds]
-
P-6 / Set PCB program: Default setting depends on model.
-
P-7 / Reset freezing cycle count: Reset freezing cycle count to zero. By reading the
freezing cycles we can tell when a unit will need to have new filtration and also how
long the unit has been in operation. This acts like the the ice machine odometer.
-
P-8 / Set drainage time: [Default: 10 seconds]
-
P-9 / Set water supply time during harvest
-
P-10 / Set bin switch error alarm
If “Y” is set, the machine rings alarm when the bin switch is not properly assembled.