background image

s

p

m

u

P

 

g

n

i

r

e

t

e

M

 

m

g

a

D

hr

iap

®

CHEM-PRO

5300 Business Drive, Huntington Beach, CA 92649    USA

Phone:

 714-893-8529     

FAX:

 714-894-9492

E mail:

 [email protected]  |  [email protected]    

URL:

 www.Blue-White.com

SERIES  C2F / C3F

Operating Manual

ProSeries

by Blue-White Ind.

TM

2

TWO-YEAR

WARRANTY

ProSeries

R

Содержание ProSeries CHEM-PRO C2F Series

Страница 1: ...Business Drive Huntington Beach CA 92649 USA Phone 714 893 8529 FAX 714 894 9492 E mail sales blue white com techsupport blue white com URL www Blue White com SERIES C2F C3F Operating Manual ProSerie...

Страница 2: ...O Schematics 9 6 0 How to Operate Chem Pro Control Pad 10 7 0 Set Remote Start Stop 11 7 1 Set FVS Flow Verification Sensor 12 8 0 Manual Operation 14 9 0 DFD Diaphragm Failure Detection 15 10 0 Alar...

Страница 3: ...rb PVDF 3 8 Tube compression PVDF 220V AC C2F263XVA C2F263XVB C2F263XVC C2F263XVD C2F261XVA C2F261XVB C2F261XVC C2F261XVD C2F262XVA C2F262XVB C2F262XVC C2F262XVD Connection Type Feed Rate at 0 PSIg C2...

Страница 4: ...to 158 F 40 C to 70 C Operating Voltage 115VAC 60Hz 1ph 1 5 Amp Maximum 230VAC 60Hz 1ph 0 7 Amp Maximum 220VAC 50Hz 1ph 1 0 Amp Maximum 240VAC 50Hz 1ph 1 0 Amp Maximum Power Cord Options 115V60Hz NEMA...

Страница 5: ...tandard 778 as a motor operated water pump CSA Standard C22 2 as process control equipment This pump complies to the Machinery Directive 98 37 EC BS EN 60204 1 Low Voltage Directive 73 23 EC BS EN 610...

Страница 6: ...rt before installing metering pump on specialized systems Metering pump should be serviced by qualified persons only Always wear protective clothing face shield safety glasses and gloves when working...

Страница 7: ...Models Injection Fitting and Strainer Suction Tubing and Strainer Suction Tubing PVC 3 8 95 cm OD X 1 4 64 cm ID PVDF PVDF O Ring TFE P optional EP O Ring TFE P optional EP Spring Hastelloy C 276 Bal...

Страница 8: ...n auto restart feature which will restore pump to operating state it was in when power was lost Note When in doubt regarding your electrical installation contact a licensed electrician Electrical conn...

Страница 9: ...232 T12 POWER F1 2 Motor Active 5 T4 FVS 3 4 5 SIG BLUE WHITE FVS SENSOR GND SIGNAL PWR RED BLACK BARE T3 REMOTE IN 3 1 2 DRY RMT COM T3 T3 1 2 POSITIVE NEGATIVE T3 T3 2 3 POSITIVE NEGATIVE T3 REMOTE...

Страница 10: ...hile in programming mode Time out Chem Pro pumps have a time out setting of approximately 20 seconds while in configuration menu If built in timer exceeds 20 seconds without a button being pressed the...

Страница 11: ...nd holding START STOP button for a few seconds until you return to Run screen Running pump with Remote Start Stop enabled REMOTE icon will always be visible on lower left side of screen Pump will disp...

Страница 12: ...a delay time in seconds Delay time is amount of time pump will wait to receive a pulse from sensor until an alarm is triggered A delay time of 00 deactivates FVS feature FVS 0 00 0 Step 5 After you ve...

Страница 13: ...dapter Thread sensor onto pump tube until tubing insert is snug against pump tube fitting do not over tighten 7 1 Set FVS flow verification system Continued Sensor Model Number Actual Working Range wi...

Страница 14: ...Runtime Screen Shot 1 Displays motor speed percentage Pump Running in Manual Operation 35 0 SPEED 35 0 REMOTE Runtime Screen Shot 2 Displays motor speed percentage Pump Running in Manual Operation wi...

Страница 15: ...le of detecting presence of a large number of chemicals including Sodium Hypochlorite Chlorine Hydrochloric muriatic Acid Sodium Hydroxide and many others System will not be triggered by water rain co...

Страница 16: ...est is most accurate for measuring injector s output in an individual installation C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Suction Tu...

Страница 17: ...able materials Manufacturer does not assume responsibility for damage to pump that has been caused by chemical attack Brush Kit Life Cycle over 3 000 hours of continuous use A spare brush kit is locat...

Страница 18: ...nnecting top and bottom may become unplugged if pulled too far apart Step 5 Unscrew and remove brush caps by turning counter clockwise Step 6 Remove used brushes and discard properly Step 7 Insert new...

Страница 19: ...Model C2x2x5 166 RPM Small Diaphragm 040 Offset 0 25 1 7 50 3 4 75 5 2 100 6 8 125 8 6 150 10 3 PSIg Bar Feed Rate LPH 18 9 3 8 7 6 11 4 15 1 175 12 0 18 9 3 8 7 6 11 4 15 1 Model C3x2x2 130 RPM 100 S...

Страница 20: ...P HEAD SM SPACER 13 90003 561 BUMPER FEET 4 90002 326 UV LCD CVR PLYCRB 1 14 6 7 8 76001 361 SUCTION TUBE 8 FOOT Not included with all models 13 14 3 2 1 22 21 21 22 71000 575 71000 447 71000 325 9000...

Страница 21: ...LVE 5 T BARB VIT 70001 348 VALVE 5 T BARB EP 8 20000 194 KIT 4 EA VALVE VIT 1 20000 195 KIT 4 EA VALVE EP 9 72000 295 DIAPHRAGM KIT C3 13 90003 561 BUMPER FEET 4 90002 326 UV LCD CVR PLYCRB 1 71010 02...

Страница 22: ...Foot Valve CHEM PRO TM tm CHEM PRO C3V Diaphragm Metering Pump Made in the USA MODE PRIME Program Minimum Maximum Blue White Ind IP66 NEMA 4X Suction Tubing Injection Check Valve Chemical Tank Discha...

Страница 23: ...t the highest quality standards in the industry Each product instruction manual includes a description of the associated product warranty and provides the user with important safety information Purcha...

Страница 24: ...an health due to the presence of hazardous substances The WEEE marking applies only to countries within the European Union EU and Norway Appliances are labeled in accordance with European Directive 20...

Отзывы: