Flowmeters are tested and calibrated for water only.

Although meters may be suitable for other chemicals, Blue-White cannot guarantee their 
suitability. It is the responsibility of the user to determine  the suitability of the flowmeter 
in their application.

Application Note

Installation Guideline

80°F / 26.7°C

100°F / 37.8°C

120°F / 48.9°C

140°F / 60.0°C

160°F / 71.1°C

180°F / 82.2°C

200°F / 93.3°C

220°F / 104.4°C

0 / 0

30 / 2.07

60 / 4.14

90 / 6.21

120 / 8.27

150 / 10.34

PSIg / BAR

Temperature

PVC Fittings

PVDF Fittings

Page 2

Page 3

F-461

F-461

Catalog Number

Description

 

Qty

Item

1

1

6

76001-330

90007-640

Union Nut (PVC)

Union Nut (ALUM)

2

2

-

Body (PSF) 

1

3

91001-159

Float Stop (PSF)

2

1

2

3

4

5

6

4

90003-134

O-ring (Viton)*

1

5

-

Float (PTFE)

1

2

2

76001-260

1.0” FPT Adpapter (PVC)

2

76001-259

1.0” FPT Adapter (PVDF)

2

Scale

Permanent dual scale silkscreen

Max Pressure

See Temperature vs. Pressure chart*

Max Temperature

See Temperature vs. Pressure chart*

Height

15” (38.1 cm)

Width

2.75” (6.99 cm)

Accuracy

± 2% of full scale reading

APPLICATION NOTES

Although meters may be suitable for other chemicals, Blue-White cannot 
guarantee their suitability. It is the responsibility of the user to determine  the 
suitability of the flowmeter in their application. 

Flowmeters are tested and 

calibrated for water only.

MAINTENANCE

The “Exploded View” drawing illustrates assembly of the F-461 series meter. 
If  your  flowmeter  needs  to  be  cleaned  refer  to  this    drawing  when 
reassembling the unit. The tapered tube may be cleaned with a soft   bottle 
brush. Use a MILD soap and water solution for cleaning purposes. Note the 
float’s “up” position.

1  The  flowmeter  must  be  installed  in  a 
vertical  plane  to  ensure  accuracy. 

Misalignment  may  damage  the  flowmeter 
and also may cause the o-ring seals to leak.

2  Use  only  PTFE  tape  on  the  threaded 
adapters.

 Pipe dope and glue will damage 

the polysulfone meter body and fittings. Or 
install  the  flowmeter  after  all  glued  fittings 
have  dried  and  fumes  have  been  purged 
from the system.

3  Mounts  and  supports  must  be  sturdy 
enough  to  support  the  plumbing  and 
prevent  vibration. 

Vibration  and  heavy 

loads will damage the meter. 

4  Avoid imposing a sudden burst of flow 
to the meter.

 Solenoid valves will damage 

the meter. Such a burst will cause the float to 
impact  the  top  float  stop  with  destructive 
force.

5  The  Maximum  fluid  temperature  is 
dependant on the working pressure.

 High 

pressure and temperature with damage the 
meter. (see temperature VS pressure chart)

TEMPERATURE vs PRESSURE

5

3

4

3

EXPLODED VIEW, PARTS LIST AND SPECS

METER SPECS

PARTS LIST

EXPLODED VIEW

*EP Option Available

ALUM = Aluminum
PSF= Polysulfone
PVC = Polyvinyl chloride
PVDF = Polyvinylidene fluoride

Shading indicates item not sold separately

1

2

Содержание F-461

Страница 1: ...ries In Line Flowmeter This flowmeter was designed to be easily installed Please read this Instruction guideline before installing your flowmeter Do not install the meter in direct sunlight The meter can be damaged by UV light Building Reliable Products that Enhance the Quality of Life ...

Страница 2: ...ll damage the polysulfone meter body and fittings Or install the flowmeter after all glued fittings have dried and fumes have been purged from the system 3 Mounts and supports must be sturdy enough to support the plumbing and prevent vibration Vibration and heavy loads will damage the meter 4 Avoid imposing a sudden burst of flow to the meter Solenoid valves will damage the meter Such a burst will...

Страница 3: ...emicals Blue White cannot guarantee their suitability It is the responsibility of the user to determine the suitability of the flowmeter in their application Flowmeters are tested and calibrated for water only MAINTENANCE The Exploded View drawing illustrates assembly of the F 461 series meter If your flowmeter needs to be cleaned refer to this drawing when reassembling the unit The tapered tube m...

Страница 4: ...se of non recommended chemicals use of non reccomended adhesives or pipe dopes excessive heat or pressure or allowing the meter to support the weight of related piping Flowmeters are tested and calibrated with water only Although meters may be suitable for other chemicals Blue White cannot guarantee their suitability Flowmeters are repaired at the factory only Call or write the factory to receive ...

Отзывы: