F-451 Series Parts

Part
Number

F-45038N
F-45030N
F-45047N
F-45039N
76000-967
F-45031
F-45032
2-136V
F-45025
F-45025-2
F-45028
F-45028-2
F-45028H
F-45028H-2
F-45034S
F-45034

Description

Union Nut
Adapter, Inline, 1” F/NPT, Polysulfone
Adapter, Inline, 1” F/NPT, Brass
Adapter, Inline, 1” sweat, Brass
Adapter, Inline, 1-1/2” F/NPT, PVC

o  

Adapter, 90 Panel Elbow, 1” F/NPT, Polysulfone
Lock nut for Panel elbow
O-ring, Viton
Wireholder, .5-6, 1-10, 2-20 gpm, 8-80 scfm
Wireholder, 3-30, 4-40 gpm
Guide Rod, 316 SS, .5-6, 1-10, 2-20 gpm, 8-80 scfm
Guide Rod, 316 SS,  3-30, 4-40 gpm
Guide Rod, Hast., .5-6, 1-10, 2-20 gpm, 8-80 scfm
Guide Rod, Hast.,  3-30, 4-40 gpm
Shield, Polycarbonate
Shield retainer adapter

Maximum Temperature vs. Pressure

Caution:

Follow these instructions to 

avoid failure.

Danger:

Wear eye protection when 

installing or removing flowmeter.

1.

 

Misalignment will damage the meter! 

Flowmeter must be installed in an exact 
vertical plane to ensure accuracy. Be 
certain of proper plumbing alignments. 
Misalignment may cause the o-ring 
seals to leak. The meterbody material 
can be damaged by UV rays. 

Do not 

install in direct sunlight.

2. Pipe dope and glue will damage 
the meter!

Use only Teflon® tape on the threaded 
adapters. Polysulfone meter body and 
fittings cannot tolerate PVC Glue 
and/or pipe dope.  Even fumes can 
cause severe damage. If you are 
installing your flowmeter to a glued 
pipe configuration, install the flowmeter 

after

 all glued fittings are dried and 

lines are purged of all fumes. 

Never

 

hold the meter body with pliers or like 
tools. Union nuts should be hand tightened only. 

DO NOT OVER-

TIGHTEN!

3. Vibration and heavy loads will damage the meter!

Wall, floor and ceiling mounts and supports must be carefully aligned 
with the meter body and sturdy enough to support the plumbing and 
prevent vibration. Never allow the flowmeter to support the weight of 
related piping.

4.

 

Solenoid valves will damage the meter!

Avoid a system that will impose a sudden burst of flow to the meter

Such a burst will cause the float to impact the float stop with destructive 
force. Solenoid valves, or other quick opening valves cannot be used 
unless meter is protected against sudden bursts of flow.

5.

 

High pressures and temperatures will damage the meter!

The maximum acceptable temperature and pressure is interdependent. 
The maximum acceptable working pressure is dependant on the actual 
fluid temperature. The maximum acceptable fluid temperature is depend-
ant on the actual working pressure. (see Temperature Vs. Pressure chart).

Installation Guideline

5

1

3

3

3

2

4

Floor

Ceiling

B

A

Dimensions

A

14-1/2”

B

3-5/16”

Inline Models

C

B

A

Dimensions

A

17”

B

15”

Panel Mount Models

C

3-5/16”

0

30

60

90

120

150

STATIC PRESSURE  (p.s.i.g)

o

o

70 F (21 C)

o

o

110 F (43 C)

o

o

150 F (65 C)

o

o

190 F (88 C)

o

o

270 F (132 C)

TEMPERA

TURE

o

o

230 F (110 C)

0

30

60

90

120

150

STATIC PRESSURE  (p.s.i.g)

o

o

70 F (21 C)

o

o

110 F (43 C)

o

o

150 F (65 C)

o

o

190 F (88 C)

o

o

270 F (132 C)

TEMPERA

TURE

o

o

230 F (110 C)

F-451 Standard Meters

F-451 SolarMeters

s

 

With 1-1/2”

 Pipe Fi

ttings

With 1” P

ipe F

ittings