Installation Guideline

Temperature vs. Pressure

Pressure

Temperature

 and 

PSIg / BAR

Temperature

130°F / 54.4°C

120°F / 48.9°C

110°F / 43.3°C

100°F / 37.8°C

90°F / 32.2°C

140°F / 60°C

80°F / 26.7°C

70°F / 21.1°C

0 / 0

50 / 3.5

100 / 6.9

150 / 10.3

200 / 13.8

250 / 17.2

Pressure and temperature limits are inversely proportional. At the maximum suggested pressure 
the temperature should approach 70°F / 21.1°C; at the maximum suggested temperature the 
pressure should approach zero psi. We cannot guarantee our flowmeters will not be damaged 
either at or below the suggested limits simply because of many factors which influence meter 
integrity; stress resulting from meter misalignment, damage due to excessive vibration and/or 
deterioration caused by contact with certain chemicals as well as direct sunlight. These situa-
tions and others tend to reduce the strength of the materials from which the meters are manu-
factured.

Flowmeters are tested and calibrated for water or air only.

F-420 Meter Installation

Although meters may be suitable for other chemicals, Blue-White cannot guarantee their 
suitability. It is the responsibility of the user to determine  the suitability of the flowmeter 
in their application.

Application Note

Please use the following steps to guide you through the 
installation.

1.

 Flowmeter must be installed in an exact vertical plane to 

ensure accuracy.

2. 

Use Teflon® tape (or similar)for the flowmeters threaded 

adapters. Acrylic and other exotic plastics cannot 
tolerate PVC Glue and/or pipe dope.  Even fumes can 
cause crazing. If you are installing your flowmeter to a 
glued pipe configuration, install flowmeter 

after

 all 

glued fittings are dried and lines are purged of all 
fumes.Never hold the meter with pliers or like tools. 

DO NOT OVER-TIGHTEN!

3. 

Wall, floor and ceiling mounts are to be carefully aligned and sturdy. Wall, floor and ceiling 

supports are recommended as needed.

4.

 Valves - 

Avoid a system that will impose a sudden burst of flow to the meter

. Such a 

burst will cause the float to impact the float stop with destructive force. Solenoid valves, 
or other quick opening valves cannot be used unless meter is protected against sudden 
bursts of flow.

5.

 Maximum working pressure not to exceed recommended psi at fluid temperature (see 

Temperature Vs. Pressure chart).         

Caution:

Follow these tips to avoid failure

Danger:

Wear eye protection when installing or removing 

flowmeter.