background image

INJECTOR

MODEL C-1100

POSITIVE DISPLACEMENT INJECTOR PUMP

OPERATING MANUAL

Models C-1100A, C -1100C, C-1100F, C-1100X

R

Blue- White

PT SARANA PRIMA ENGUNA

Jl.Gunung Sahari Raya 84 C

Jakarta - 10610

Phone: 021 4200045 Fax: 021 4200483

Website: www.spe.co.id

Содержание CHEM-FEED C-1100

Страница 1: ...OSITIVE DISPLACEMENT INJECTOR PUMP OPERATING MANUAL Models C 1100A C 1100C C 1100F C 1100X R Blue White PT SARANA PRIMA ENGUNA Jl Gunung Sahari Raya 84 C Jakarta 10610 Phone 021 4200045 Fax 021 420048...

Страница 2: ...ttings 10 6 How to operate the Pump 11 6 1 How to adjust the output manual stroke adjustment 11 6 2 Fixed cycle timer models 12 6 3 Variable speed model 12 6 4 FVS Flow Verification System 13 7 How to...

Страница 3: ...sing the C 1100 Model E positive displacement Metering Pump The C 1100 is designed to inject chemicals into piping systems and is capable of injecting against system pressures up to 150 PSI 10 4 bar I...

Страница 4: ...to a solid surface only Mounting to drywall with anchors is not recommended Mount the pump close to the injection point Keep the outlet discharge tubing as short as possible Longer tubing increases t...

Страница 5: ...rge Tube Strainer Ceramic Weight Injection Check valve with 1 4 and 1 2 male pipe threads Mount in upward position to prevent trapped gasses in the injection fitting Wall or shelf mount away from the...

Страница 6: ...nking current MA MOTOR ACTIVE OPEN COLLECTOR OUTPUT The output brown wire sinks to DC ground when the motor is de energized 6 30Vdc collector voltage 50mAdc maximum sinking current All signal wires mu...

Страница 7: ...ge 7 T1 T2 230VAC T3 T4 HOT LOAD 120 VAC MA AL TFD FVS SIG FVS FLOW VERIFICATION SENSOR INPUT AL OPEN COLLECTOR ALARM OUTPUT MA OPEN COLLECTOR MOTOR ACTIVE OUTPUT CIRCUIT BOARD SIGNAL CONNECTION C 110...

Страница 8: ...UTRAL LEADWIRE GROUND LEADWIRE 230VAC 60Hz YELLOW YELLOW YELLOW BLUE BROWN RED GREEN GREEN GREEN MOTOR LEADWIRES CIRCUIT BOARD SIGNAL IN OUT CONNECTIONS WIRE COLOR CODE SYSTEM DESCRIPTION FVS FLOW VER...

Страница 9: ...FVS SIG T1 T2 230VAC T3 T4 HOT LOAD COMMON OPTIONAL POWER INDICATOR LAMP HOT HOT 108 130 VAC PURPLE BLACK CYCLE ADJUSTMENT POTENTIOMETER OPTIONAL INJECTOR INDICATOR LAMP 120 VAC 208 240 VAC NEUTRAL AC...

Страница 10: ...g Installation The Injection Check valve fitting is designed to install directly into either 1 4 or 1 2 female pipe threads This fitting will require periodic cleaning especially when injecting fluids...

Страница 11: ...s stroke length to an infinite number of settings within the flow range Note The pump s output will reduce due to increased system pressure increased suction lift and increased fluid viscosity The pum...

Страница 12: ...far enough to open the control panel door Turn the adjustment knob to the desired percentage of on time per cycle Note When power is applied to the pump the pump will either automatically begin to pum...

Страница 13: ...during pump operation This could indicate a clogged injection fitting empty chemical solution tank loose tubing connection etc The system features an alarm delay time of 6 seconds which allows the pum...

Страница 14: ...iped free of any dirt and debris Periodically clean the injection check valve assembly especially when injecting fluids that calcify such as sodium hypochlorite These lime deposits and other build ups...

Страница 15: ...suction tubing from the graduated cylinder and refill the graduated cylinder if necessary Note the amount of solution in the gradu ated cylinder 6 Place suction tubing with the Footvalve Strainer inst...

Страница 16: ...70 2 1 4 3 5 6 8 7 9 10 11 12 13 14 15 17 25 27 28 24 23 22 18 19 21 20 26 29 31 30 33 32 36 37 35 34 38 39 40 41 43 38 44 45 47 48 50 51 52 49 54 53 57 58 56 55 59 51 52 60 61 62 63 65 64 66 67 68 16...

Страница 17: ...1 19 90006 006 Return Spring 2 20 90002 001 Slide Bearing 2 21 76000 172 Stirr up 1 22 90002 017 Dial Knob 1 23 90011 168 Screw 6 x 62 PH oval A 4 24 90011 121 Thumb Screw 6 32 x 1 125 1 25 71000 363...

Страница 18: ...pochlorinators they are meant to destroy bacteria and algae contamination before it s removal by filtration Acid and soda injectors are used for PH control balance Blue White injectors are factory tes...

Страница 19: ...80000 363 Rev 1 12 2006 R Blue White PT SARANA PRIMA ENGUNA Jl Gunung Sahari Raya 84 C Jakarta 10610 Phn 021 4200045 Fax 021 4200483 www spe co id...