Page 20
®
FlexFlo A1A
4. Press the Start & Stop key to start the pump and set the pump to 6 GPD (1 LPH).
5. With the pump running, pull the inlet (suction) fitting out of the pump head. Guide the tube counterclockwise
away from the rollers.
Page 21
®
FlexFlo A1A
11.3 Tube Installation
NOTE
: Thoroughly clean the pump head and rotor. The rotor can be removed by pulling it straight out. After
cleaning, push the rotor back on the shaft.
1. Press Start & Stop key to start the pump.
2. Insert the inlet (suction) side of the pump tube fitting into the lower retaining slot of the pump head. Carefully
guide the pump tube into the pump head.
6. Pull the outlet (discharge)fitting out of the pump head.
7. Press the Start & Stop key to stop the pump.
3. Stretch the tube slightly and insert the outlet (discharge) fitting into the upper retaining slot of the pump head.