EXPLODED VIEW, PARTS LIST AND SPECS

INSTALLATION GUIDE

Page 2

Page 3

F-451

APPLICATION NOTES

Although meters may be suitable for other chemicals, Blue-White cannot 
guarantee their suitability. It is the responsibility of the user to determine  the 
suitability of the flowmeter in their application. 

Flowmeters are tested and 

calibrated for water only.

MAINTENANCE

The  “Exploded  View”  drawing  illustrates  assembly  of  the  F-451N  series 
meter. If your flowmeter needs to be cleaned refer to this   drawing when 
reassembling the unit. The tapered tube may be cleaned with a soft   bottle 
brush. Use a MILD soap and water solution for cleaning purposes. Note the 
float’s “up” position.

Temperature

190°F / 87.7°C

170°F / 76.6°C

150°F / 65.6°C

130°F / 54.4°C

110°F / 43.3°C

210°F / 98.9°C

90°F / 32.2°C

70°F / 21.1°C

0 / 0

30 / 2.1

60 / 4.1

90 / 6.2

230°F / 110°C

MODELS WITH PVC 

ADAPTERS

MODELS WITH BRASS 

ADAPTERS

MODELS WITH BRASS 

ADAPTERS

2

3

4

3

1  The  flowmeter  must  be  installed  in  a 
vertical  plane  to  ensure  accuracy. 

Misalignment  may  damage  the  flowmeter 
and also may cause the o-ring seals to leak.

2  Use  only  PTFE  tape  on  the  threaded 
adapters.

 Pipe dope and glue will damage 

the polysulfone meter body and fittings. Or 
install  the  flowmeter  after  all  glued  fittings 
have  dried  and  fumes  have  been  purged 
from the system.

3  Mounts  and  supports  must  be  sturdy 
enough  to  support  the  plumbing  and 
prevent  vibration. 

Vibration  and  heavy 

loads will damage the meter. 

4  Avoid imposing a sudden burst of flow 
to the meter.

 Solenoid valves will damage 

the meter. Such a burst will cause the float to 
impact  the  top  float  stop  with  destructive 
force.

5  The  Maximum  fluid  temperature  is 
dependant on the working pressure.

 High 

pressure and temperature with damage the 
meter. (see temperature VS pressure chart)

TEMPERATURE vs PRESSURE

1

Meterbody (PSF)

7

-

1

Float (SS)*

6

-

Catalog

Description

 

Qty

Item

8

F-45028

F-450028-2

1

4

2-136V

O-Ring 2-136 (Viton)**

1

9

F-45046
F-45054

Wireholder, .5-6, 1-10, 2-20 

(PSF)

Wireholder, 3-30, 4-40 

(PSF)

1

5

2-006A
2-008V

Float Stop .5-6, 1-10, 2-20 (Aflas)

Large Float Stop, 3-30, 4-40 (Aflas)

1

3

F-45025

F-45025-2

Wireholder 1-10, 2-20 

(PSF)

LG Wireholder  3-30, 4-40 

(PSF)

2

2
2

Adapter, vertical, 1” F/NPT (PSF)

Adapter, vertical, 1-1/2” M/NPT (PVC)

2

F-45030N

F-45036

1

F-45038N

Union Nut

2

Guide Wire, .5-6, 1-10, 2-20, (SS)*

Guide Wire, 3-30, 4-40 (SS)*

1

2

3

4

6

7

8

9

5

5

Scale

Permanent dual scale silkscreen

Max Pressure

See Temperature vs. Pressure chart*

Max Temperature

See Temperature vs. Pressure chart*

Height

14.5” (368mm)

Width

3.1875” (81mm) 

Accuracy

± 2% of full scale reading

*Hastelloy C-276 Option Available
**EP Option Available

PSF= polysulfone
SS = # 316 Stainless Steel
PP = polypropolyne
PVC = Polyvinyl chloride

Shading indicates item not sold separately

METER SPECS

PARTS LIST

EXPLODED VIEW

PSIg / BAR

www.calcert.com

[email protected]

1.800.544.2843

0

5

10

15

20

25

30