background image

4. Motor bearings noisy from normal wear, rust, overheating, or concentration of chemicals causing seal damage
which will allow chlorinated water to seep into bearings wiping out the grease causing bearing to whine.

Solution:

All seal leaks should be replaced at once.

page 12

TECHNICAL DATA

B.W.No.

HTA/HTI

HP

Voltage

Hertz

Amps

Flow Rate

NE4517

HTI100

1.0

115/230

60

13/6.5

86GPM

NE4518

HTI150

1.5

115/230

60

15/7.5

90GPM

NE4519

HTI2SP075

0.75/0.23

230

60

/ .6

80/35GPM

NE4520

HTI2SP100

1.0/0.3

230

60

1

6 /1.8

86/38GPM

NE4521

HTI2SP150

1.5/0.39

230

60

7.5/2.1

90/42GPM

NE4522

HTI2SP200

2.0/0.4

230

60

11/2.4

92/44GPM

NE4513

HTA075

0.75

115

60

9.2

84GPM

NE4514

HTA100

1.0

115

60

12

88GPM

NE4515

HTA2SP075

0.75/0.28

115

60

10/3.2

84/37GPM

NE4516

HTA2SP100

1.0/0.3

115

60

11/3.4

88/40GPM

NEP4208

HTA2SP150

1.5/0.39

230

60

7.5/2.1

90/42GPM

5

Содержание Flow Xtreme NE4513

Страница 1: ...REPLACEMENT PUMPS OWNER S MANUAL INSTALLATION OPERATION PARTS NE4513 NE4515 NEP4208 NE4514 NE4516 NE4517 NE4520 NE4518 NE4521 NE4519 NE4522 NE4523 NEP4268 NEP4269 VER 0611 NE4524 NEP4271...

Страница 2: ...so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly advised to protect the electri...

Страница 3: ...tion outlets and or suction outlet covers which are damaged broken cracked missing or unsecured can cause severe injury and or death due to the following entrapment hazards Hair Entrapment Hair can be...

Страница 4: ...nd water is discharged All suction and discharge valves MUST be OPEN when starting the circulation system Failure to do so could result in severe personal injury and or property damage WARNING Separat...

Страница 5: ...Allow adequate access for servicing pump and piping Pipe Sizing Chart NOTE It is recommended that a minimum length of piping MAXIMUM RECOMMENDED SYSTEM FLOW RATE BY PIPE SIZE Pipe Size mm 1 32 1 1 4 4...

Страница 6: ...electrical shock hazard WARNING Do NOT ground to a gas supply line WARNING To avoid dangerous or fatal electrical shock turn OFF power to motor before working on electrical connections WARNING Ground...

Страница 7: ...5 ft 1 5 m of inside walls of swimming pool spa or hot tub Wiring WARNING All wiring must be done by a licensed electrician Pump MUST be permanently connected to circuit If other lights or appliances...

Страница 8: ...t in severe personal injury Release all pressure from filter pump and piping system See filter owner s manual If water source is higher than the pump pump will prime itself when suction and outlet val...

Страница 9: ...in the system Drain all water from pump and piping when expecting freezing temperatures or when storing pump for a long time see instructions below Keep motor dry and covered during storage To avoid...

Страница 10: ...r power drop frequently caused by undersized wiring or extension cord use Solution Contact qualified professional to check that the wiring gauge is heavy enough NOTE Your pump motor is equipped with a...

Страница 11: ...seal only if it is leaking Low Flow Generally Check For 1 Clogged or restricted strainer or suction line Solution Contact a qualified repair professional 2 Undersized pool piping Solution Correct pip...

Страница 12: ...tz Amps Flow Rate NE4517 HTI100 1 0 115 230 60 13 6 5 86GPM NE4518 HTI150 1 5 115 230 60 15 7 5 90GPM NE4519 HTI2SP075 0 75 0 23 230 60 6 80 35GPM NE4520 HTI2SP100 1 0 0 3 230 60 1 6 1 8 86 38GPM NE45...

Страница 13: ...19 8 IMPELLER OF ITEM HTI 100 HTI2SP 100 HTI010 NEP4218 NE4517 NE4520 8 IMPELLER OF ITEM HTI 150 HTI2SP 150 HTI011 NEP4219 NE4518 NE4521 8 IMPELLER OF ITEM HTI 200 HTI2SP 200 HTI012 NEP4220 NE4522 9 O...

Страница 14: ...4 All 9 PUMP COVER HTA011 NEP4195 All 10 O RING HTA012 NEP4196 All 11 IMPELLER OF ITEM HTA 075 HTA2SP 075 HTA014 NEP4198 NE4513 NE4515 IMPELLER OF ITEM HTA 100 HTA2SP 100 HTA015 NEP4199 NE4514 NE4516...

Страница 15: ...5 43 O ring B 3 1 P00183 NEP4266 All 6 44 O ring C 1 5 1 P00184 NEP4267 All 7 45 Strainer Collar 1 P00133 NEP4247 All 8 46 Strainer Basket 1 P00134 NEP4248 All 9 47 Pump Drain Cap 1 P00135 NEP4249 All...

Отзывы: