Possible Reasons
No.
Problem
Cause
Rectification
1
Electrical shock from
the device.
1.Check the power cable is damaged or
not.
2.Check the electrical wire connector is
loose or damaged.
3.Ensure that electrical wire or connector
is not wet.
1.Change the power adapter.
2.Connect the connector tightly.
3.Clean the wire and connector.
2
LED Indicator is not
working
1.Power supply is not connected.
2.SMPS is defective/damaged.
3.Multiplex connector is not connected or
loosely connected.
4. Electrical wiring connection is not
correctly connected
5.LED Indicator is defective/damaged.
1.Check the input power supply is ON
2. Ensure that multiplex connector is
connected to LED connector
3.Check the 24V DC supply is coming from
the SMPS.
4. Check the electrical wiring connection is
proper or not.
5. Change the touch sensor / LED display.
3
Output Water TDS is
very high.
1.R.O. Membrane is not in housing.
2.Pipe connection of filtered water &
reject water is interchanged.
3.FRT is not connected or defective
FRT/improper rated FRT.
4.Brine seal could be damaged.
1.Ensure that R.O. Membrane is present in
housing.
2.Do proper tubing connection.
3.Connect the FRT to the reject of RO or
Replace the FRT
4.Change RO membrane.