background image

9.  Technical Information

This next section outlines the components, specifications and performance 
data that make this product such a uniquely high value. 

In order to continually improve all of its products Blue Sky reserves the right 
to change these specifications without notice.

SUB 15 Universal Active Subwoofer

Enclosure

* .75” MDF with 1” front and rear baffle and internal bracing
* Isolation feet included
* Dimensions: 20.75” H x 18” W x 20.63” D (inc / heatsink and grill)
* Weight 125 lbs. / 56.69 kg

15” Hemispherical Woofer

* 15-inch high excursion (2.36” peak to peak) woofer with a vented 20+ Lbs. 
motor (total driver weight = 36 Lbs.)
* Cast aluminum frame
* Dual 2.5” high temperature voice coils
* Dual progressive spiders
* Mica filled polypropylene cone w/ Santropene surround
* Fully video shielded 

Electrical Specification

* Input Voltage 

115/230 VAC 50/60Hz switchable

* Wattage   

1600 Watts

* Fuse 

 

115VAC 8A - 250 V 5x20mm (Time Delay or Slo-Blo)

 

 

230VAC 15A - 250 V 5x20mm (Time Delay or Slo-Blo)

Amplifier

* Class D design
* 1000 Watts RMS into 4-Ohm
* .1% THD + noise at rated power @ 1kHz
* XLR balanced input
* Adjustable gain control
* Voltage Sensitivity 100mv=90dB SPL@1m

Switchable low frequency response characteristic:

* Frequency Resp. 30Hz mode  +/-3dB  30Hz to 200Hz
* Frequency Resp. 20Hz mode  +/-3dB  20Hz to 200Hz
* Low Frequency Cutoff (20Hz mode)       -3dB @ 20Hz
           (see figure 4 for specific measurement data)

Bass-Management Section

* Input impedance    

 

20K balanced

* Common mode rejection  

 

40dB typical @ 60Hz

* Maximum Input Level  

 

+24dBu balanced

* Output Impedance  

 

200 Ohms balanced

* Nominal gain  

 

 

0dB

* SUB IN low pass filter  

 

None

Switchable Filter Settings

 

* BLUE SKY Mode

 

 

High Pass Filter  

80Hz 2nd Order

 

 

Low Pass Filter 

80Hz 4th Order

 

* Universal Mode

 

 

Dual independently tunable state variable high pass  

 

 

and low pass filters

 

 

Frequency Range 

50Hz to 160Hz

 

 

Filter Slope 

4th Order   

Page 11

Figure 4

Содержание SUB 15 UNIVERSAL

Страница 1: ...Blue Sky International 70 Sea Lane Farmingdale NY 11735 www abluesky com Owner s Manual Version 1 9R January 18 2005 Blue Sky SUB 15 Universal 1000 Watt subwoofer with adaptive x over ...

Страница 2: ...up with filter setting instructions _ _ Page 5 5 System Signal Connections _ __ __ __ __ __ __ _ Page 6 6 Expanded Calibration Guide _ __ __ __ __ __ _ Page 7 7 A Tour of the Amplifier and I O _ __ __ __ __ _ Page 8 8 Subwoofer Placement Guide _ __ __ __ __ __ _Page 10 9 Technical Information _ __ __ __ __ __ __ __ __ _Page 11 10 SUB 15 Universal Cabinet Dimensions _ __ __ _Page 12 11 Factory Serv...

Страница 3: ... lightning and power line surges 10 OVERLOADING Do not overload wall outlets or extension cords as this can result in a risk of fire or electric shock 11 LIQUID ENTRY Never spill any liquid of any kind on the product 12 SERVICING Do not attempt to service this product yourself Opening or removing covers including any over bottom or side speaker drivers may expose you to dangerous voltage or other ...

Страница 4: ...ubwoofer brings you years of accurate and problem free operation We ask that you take the time to read this manual register the product and visit our website for any updated information regarding this product If you have any questions please don t hesitate to contact us www abluesky com Thank you for choosing Blue Sky 2 Important notes about the SUB 15 Universal and this Owner s Manual Voltage Sel...

Страница 5: ...ring system 10 It is now time to set the Variable Cutoff Frequency on the back of the SUB 15 Universal to best match your monitoring system if you are using the SUB 15 Universal with Blue Sky monitors set the Filter Selector Switch to BLUE SKY and skip to item 11 To determine the proper filter setting on the SUB 15 Universal you first need to know the cutoff frequency of your monitors This can typ...

Страница 6: ...INPUTS ELECTRONICALLY BALANCED Figure 2 The SUB 15 Universal s XLR inputs can handle up to 24dBu of signal level at the input and are compatible with most if not all professional gear Additional adaptor cables can be purchased from most professional audio dealers so that the SUB 15 Universal can be used with other output types TRS RCA etc Figure 3 FLAT POSITION IS ALL SWITCHES DOWN FLAT POSITION I...

Страница 7: ...5 Universal monitors Step 5 Assign the 500 2 5kHz pink noise signal to the left channel only Make sure there is nothing coming from the right channel or any other channels Because this signal is bandwidth limited you don t have to worry about turning the sub off There are two methods of setting the levels A If you have a master monitor level control you can set the sat gain control at reference an...

Страница 8: ...Page 8 7 A Tour of the SUB 15 Universal Amplifier and I O ...

Страница 9: ...TSINK The heatsink provides essential cooling to the amplifier inside the SUB 15 Universal Please ensure that proper air circulation is available for proper cooling 9 SUB GAIN This knob controls the input sensitivity of the subwoofer amplifier only When set to the reference position a 100mV signal at the input equals 90dB output at a meter 10 LF Extension One of the SUB 15 Universal s unique featu...

Страница 10: ...and definition You are not just listening for the most boom but rather where the bass is most accurate and natural sounding Remember because the subwoofer is basically omni directional the best spot for the subwoofer can be next to or even behind the main monitoring area After finding the spot where the subwoofer has the best response in the room place the subwoofer in that location Now listen fro...

Страница 11: ...ltage 115 230 VAC 50 60Hz switchable Wattage 1600 Watts Fuse 115VAC 8A 250 V 5x20mm Time Delay or Slo Blo 230VAC 15A 250 V 5x20mm Time Delay or Slo Blo Amplifier Class D design 1000 Watts RMS into 4 Ohm 1 THD noise at rated power 1kHz XLR balanced input Adjustable gain control Voltage Sensitivity 100mv 90dB SPL 1m Switchable low frequency response characteristic Frequency Resp 30Hz mode 3dB 30Hz t...

Страница 12: ...Page 12 10 SUB 15 Universal Cabinet Dimensions ...

Страница 13: ...e that occurs due to non factory packaging 4 Include a legible note stating your name shipping address no P O boxes daytime phone number RA number and a detailed description of the problem including how it can be duplicated 5 Write the RA number on the top of the carton 6 Ship the product to the address below We recommend United Parcel Service UPS Please insure the product regardless of shipping m...

Страница 14: ......

Страница 15: ......

Страница 16: ...Blue Sky International 70 Sea Lane Farmingdale NY 11735 www abluesky com ...

Отзывы: