![Blue Seal GP8120G Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/blue-seal/gp8120g/gp8120g_installation-and-operation-manual_2776504025.webp)
23
Gas Conversion and Specifications
Commissioning
Before leaving the converted installation;
1.
Check all gas connections for leakages using soapy water or other gas detecting equipment.
2.
Check the following functions in accordance with the operating instructions specified in the
‘Operation’ section of this manual.
•
Light the Pilot Burner.
•
Light the Main Burner.
•
Check the ‘Low Fire’ burner operation.
•
Check the ‘High Fire’ Burner operation.
•
Ensure that all the controls operate correctly.
•
Ensure that the operating pressure remains correct.
3.
Ensure any adjustments done to components that have the adjustments / settings sealed (e.g. paint
sealed) are re-sealed.
NOTE: If for some reason it is not possible to get the appliance to operate correctly, shut off the
gas supply and contact the supplier of this appliance.
WARNING: