35
A
Appendix A: Gas Type Conversion
Revision 1/
© Moffat Ltd, January 2007
Blue Seal Evolution Series Gas Chargrills
Pilot Burners
1.
To remove the pilot burner, disconnect the gas sup-
ply tube from the base of the pilot burner.
NOTE; Do not remove the mounting plate securing
the pilot burner and thermo couple to the
Chargrill. Fig 14 shows Pilot Burner
Retaining Plate removed for clarity only.
2.
Unscrew the base nut from the pilot burner and using
a small screwdriver,withdraw injector from inside the
pilot burner.
3.
Determine the correct injector size for the corre-
sponding gas from the rating plate attached to the
inner bulkhead adjacent to the manifold test point
behind the front control panel.
4.
Fit the new pilot injector into the rear of the pilot
burner and push fully home.
5.
Re-connect the gas supply tube to the base of the
pilot burner and tighten.
Gas Supply Tube
Fig 12
Thermocouple
Pilot Burner
Piezo Igniter
Unscrew Gas
Supply Tube Here
Fig 14
Thermocouple/Pilot
Burner/Igniter
Retaining Plate
Unscrew Gas
Supply Tube Here
Fig 13