5
Fault Finding
10
Amendment 6
© Moffat Ltd, August 2015
Blue Seal Evolution Series Electric Dedicated Griddle Ranges
5.1 Fault Finding Chart
Fault
Possible Cause
Remedy
Griddle plate does not heat. (Green light
not illuminated).
The mains isolating switch on the wall,
circuit breaker or fuses are ‘Off’ at the
power board.
Turn ‘On’ mains isolating switch.
Ensure power supply is correct.
Griddle plate slow to heat up / recover
heat.
One element faulty.
(Refer Fault Diagnosis 5.2.1).
Replace element.
(Refer Service Section 6.2.3).
No heat control.
Thermostat faulty.
(Refer Fault Diagnosis 5.2.1).
Replace thermostat.
(Refer Service Section 6.2.1).
No indicator light.
Faulty indicator.
Replace indicator.
(Refer Service Section 6.2.5).
Griddle plate does not heat.
Green light illuminated, but amber light not
illuminated.
Thermostat faulty.
(Refer Fault Diagnosis 5.2.1).
Overtemp thermostat tripped or faulty.
Replace thermostat.
(Refer Service Section 6.2.1).
Reset / replace overtemp thermostat.
(Refer Service Section 6.2.4).
5.1.1 Griddle