Battery Temperature Compensation

Battery temperature compensation is output voltage regulation based on battery temperature variances. Since batteries 
can see extreme temperature differences, it is important to regulate output voltage with temperature to maximize battery 
life. A battery in a cold environment should not be charged at the same voltage as a battery in a hot environment. The 
BatteryLink® Charger is set at a baseline of 25°C. If the included battery temperature sensor is installed, then any 
variance from this baseline will result in a change in output voltage.  Voltage will decrease at higher temperatures, 
and increase at lower temperatures. The temperature sensor also allows the charger to react to extreme hot or cold 
temperatures (below -20°C or above 45°C) by reducing output or shutting down to preserve the battery. Reference the 
Installation Instructions on page 6 and the Full Installation Diagram on page 8 for details on how to install the battery 
temperature sensor.

Automatic Charging Relay (ACR)

The BatteryLink® Charger includes an integrated 170A Automatic Charging Relay (ACR).  The purpose of an ACR is to 
combine batteries for charging, but leave them isolated for discharge. This works well with dual battery systems, where 
non-starting loads are isolated from the engine starting battery to reduce the risk of being stranded on the water without 
enough power to start your engine.  The ACR in the BatteryLink® Charger will combine the auxiliary and start batteries at 
or away from the dock. This means both batteries will be charged during AC powered charging, or when AC power is not 
available and a secondary charging source is active, such as your engine’s alternator. The ACR includes an optional Start 
Isolation feature, which can be used to prevent engine starting current being drawn from the auxiliary battery. Start 
Isolation protects sensitive electronics wired to the auxiliary battery from being affected by voltage sags or spikes caused 
by engine starting. The ACR also includes an optional Manual Combine feature, which allows manually closing the ACR 
to parallel the batteries using a remote switch. This can be used to jump start from the auxiliary battery in the event of 
a dead start battery. Reference the Installation Instructions on page 6 and the Full Installation Diagram on page 8 for 
details on how to wire the Start Isolation and Manual Combine features.

LED Status Indicators

Green solid AC power

Off

No AC power

Green solid

Combined - ACR closed

2x-flash

SI present, battery temp outside range of 

-20°C to 49°C, or reverse battery polarity 

detected - ACR open

3x-flash

Manual Combine input present - ACR closed

Off

Battery voltages below threshold - ACR open

Green solid Charge complete - 

Float/rest stage

Amber solid Charge in progress - 

Bulk or absorption stage

Red

single blink

Battery hot - Charger shutdown 

(>= 49°C, recovers at 47°C)

Red

double blink

Battery hot - Output reduction

(>= 45°C, recovers at 43°C)

Red

triple blink

Battery cold - Charger shutdown 

(<= -20°C, recovers at -18°C)

Red solid

Battery polarity reversed

Off

No AC power

DC Power

Solid Combined - ACR closed
Off

Separated - ACR open

AC Power

Solid Charging complete - Float/rest stage

Flash Charge in progress - Bulk or absorption

Or error state - See charger LEDs

AC POWER

BATTERY

ACR STATUS

CHARGE STATUS

Содержание Battery LINK 7606

Страница 1: ...s for the BatteryLink Chargers This User Manual describes the product mentioned herein at the time of its publication Specifications and performance are subject to change at the discretion of Blue Sea Systems To view the most current revision of this publication visit bluesea com products 7606 Scan for additional product information YEAR WARRANTY ...

Страница 2: ...er or other means for disconnection from the supply mains must be incorporated in the fixed wiring to the charger in accordance with wiring rules e The AC supply cord should be protected by a Residual Current Device RCD suitable for personal shock protection Make AC connection in a secure manner that will avoid contact with water 7 DO NOT OPERATE CHARGER IF IT HAS A DAMAGED CORD has received a sha...

Страница 3: ...ions cover snaps in place to insulate terminations MULTISTAGE CHARGER INTEGRATED ACR Remote LED included Battery temperature sensor included PN 1820 DC Output Battery negative connection 1 4 20 studs accept 1 4 or M6 ring terminals Use 7 16 socket wrench Tighten to 60 in lb 6 78 Nm Do not overtighten Battery positive connections 3 8 16 studs accept 3 8 or M10 ring terminals Use 9 16 socket wrench ...

Страница 4: ...the battery up to the absorption voltage Once the absorption voltage is reached the charger enters absorption mode This is a constant voltage mode in which the battery is held at the absorption voltage to complete the last 20 25 of charging In the absorption stage current will decrease according to the batteries needs plus any additional current required for active loads The length of time spent i...

Страница 5: ... or away from the dock This means both batteries will be charged during AC powered charging or when AC power is not available and a secondary charging source is active such as your engine s alternator The ACR includes an optional Start Isolation feature which can be used to prevent engine starting current being drawn from the auxiliary battery Start Isolation protects sensitive electronics wired t...

Страница 6: ...itive Wire sized for maximum alternator output Negative Wire sized for 20A charger output Alternator up to 30A Alternator up to 60A Alternator up to 120A Alternator up to 170A 6 ft 1 83 meters NO 8 AWG 10 mm 6 AWG 16 mm 2 AWG 35 mm 1 0 AWG 70 mm 10 AWG 6 mm YES 8 AWG 10 mm 4 AWG 25 mm 1 0 AWG 70 mm 3 0 AWG 95 mm 10 AWG 6 mm 10 ft 3 05 meters NO 6 AWG 16 mm 4 AWG 25 mm 1 AWG 50 mm 1 0 AWG 70 mm 8 A...

Страница 7: ...attach the sensor in the center between multiple batteries When external circumstances could create a significant difference in temperature on one side of a battery versus another always attach the sensor on the warmest side NEVER pierce the battery casing with a screw or other fastener Extend sensor wires as necessary to reach the charger using appropriate fully insulated butt connectors or a ter...

Страница 8: ...lue Ground Green Yellow ENGINE DC SAFETY GROUND See Wire Size and Fuse Rating Table page 5 Wire size and fuse rating based on house loads For more information use the Circuit Wizard at circuitwizard bluesea com DC safety ground wire must be no more than one nominal wire size smaller than the positive battery wires If the rating of the circuit protection used in the positive battery wires is greate...

Страница 9: ...Y START BATTERY 2A FUSE 16 AWG 1 5mm FUSE 7606 AC AC Connections Line Brown Neutral Blue Ground Green Yellow DC SAFETY GROUND OPTIONAL COMBINE SWITCH sold separately YELLOW WIRE RED WIRE ENGINE See Wire Size and Fuse Rating Table page 5 Wire size and fuse rating based on house loads For more information use the Circuit Wizard at circuitwizard bluesea com DC safety ground wire must be no more than ...

Страница 10: ...COVER REMOVED THIS VIEW SHOWN WITH COVER REMOVED FOR OPTIMAL PERFORMANCE MOUNT VERTICALLY AS SHOWN IN A WELL VENTILATED AREA RECOMMENDED MOUNTING CLEARANCE 175mm MINIMUM ON ALL SIDES 90 22 90mm STUD HEIGHT TYP 2X 44 11 1mm STUD HEIGHT 1 09 27 6mm TERMINAL HEIGHT TYP 3X 42 10 7mm STUD HEIGHT 8 63 219 1mm 23 5 9mm TERMINAL HEIGHT 2 60 66 0mm 4 29 108 9mm 7 67 194 8mm TYP 2X 0 0 0mm 0 0 0mm TYP 2X 5 ...

Страница 11: ...13 5V 30 sec ACR Open Voltage 12 75V 10 sec 12 35V if voltage is rising ACR Manual Combine Timeout 10 minutes Operating Current no AC power 10mA Negative Terminal Stud Size 1 4 20 accepts M6 ring terminal Maximum 1 4 Terminal Stud Torque 60 in lb 6 8 Nm Positive Terminal Stud Size 3 8 16 accepts M10 ring terminal Maximum 3 8 Terminal Stud Torque 140 in lb 15 8 Nm Quick Connect Terminal Size 1 4 x ...

Страница 12: ...ted emission EN61000 3 2 Harmonics EN61000 3 3 Voltage fluctuations and flicker Immunity EN 55014 2 2015 EN61000 4 2 Electrostatic discharge EN61000 4 3 RF electromagnetic field EN61000 4 4 Fast transient EN61000 4 5 Surges EN61000 4 6 RF conducted disturbances EN61000 4 11 Voltage dips and interruptions Ignition Protection ISO 8846 ed 1 The notified body HPi Verification Services Ltd NB 1521 perf...

Отзывы: