Chapter 4: 

Utilizing Your Training Model

 

9

 

 

 

 

 
 
 
 

Using Your Training Model 

(continued)

 

3.    When utilizing ultrasound guidance, place ultrasound gel on the model or on the

 

ultrasound  transducer in adequate quantities so that the probe slides effortlessly across 
the surface of the model.  Add more gel as necessary.

 

4.    Adjust the ultrasound system controls per the manufacturer’s instructions, increasing and

 

decreasing the depth and gain controls until the desired image is obtained. 

 

If you intend on guiding sharp objects into the phantom, never place the model in a 
location where you might accidentally puncture yourself.

 

 

 
 

Using Needles and Catheters

 

 

1.    For best performance, we recommend that you utilize new, sharp, unbent 18-21 

gauge needles and associated catheter kits when accessing the structures in the 
model; you may use up to 7-French Triple-Lumen catheters.

 

2.    Do not use any needle larger than 18 gauges or permanent damage to your 

model may occur.

 

3.    Smaller bore needles (>21 gauge) can bend during use and damage your model’s

 

simulated tissue.

 

4.    Aggressive repositioning of needles rather than removing and repositioning can 

cause stubborn or permanent needle tracks due to the needle tip dragging through 
the simulated tissue.

 

5.    Dull needles may also cause permanent damage to the tissue.  It is important to 

replace needles approximately every ten cannulations.

 

 

 
 

Accessing Simulated Blood Vessels

 

1.    Users can create a pulse in the ulnar and radial arteries in the wrist only by lightly pressing 
the hand bulb to differentiate vessels from artery. Veins are collapsible with light pressure from 
transducer.

 

2.    Users can remove fluid after the vessels have been properly cannulated to confirm needle

 

placement.  Please note that any fluid withdrawn from the vessel will require refilling.

 

 

Lack of fluid will result in diminished ultrasound image.  

For instructions on refilling 

your model, please refer to Chapter

 4: Utilizing Your Training Model—Refilling Your 

Training Model 

on page 10 of this User Guide.

 

Содержание BPA304

Страница 1: ...Instructions and User Guide Arm Ultrasound Training Model for PICC I V and Arterial Access BPA304 January 6th 2017 Rev 3 0...

Страница 2: ...Introduction to Your Training Model 6 Quick Facts about Your Training Model 7 Chapter 4 Utilizing Your Training Model 7 Anatomy of Your Training Model 8 Using Your Training Model 9 Using Needles and C...

Страница 3: ...ill through experience That is why we offer you the best ultrasound simulation training available Blue Phantom Warranty Blue Phantom takes pride in its quality design and manufacturing standards Our p...

Страница 4: ...should be adhered to 5 Follow Instructions All operating and maintenance instructions should be followed 6 Weight Warning Product weight is approximately 20lbs 9kg 7 Care must be taken to place the mo...

Страница 5: ...ansducer for ultrasound guided vascular access procedures Ultrasound gel Optional Accessories for Your Training Model Blue Phantom Red Ultrasound Refill Solution BRS180 Red Blue Phantom Blue Ultrasoun...

Страница 6: ...ured Models configured with the following Vascular Anatomy Cephalic Vein Radial Vein Basilic Vein Ulnar Vein Medial Cubital Vein Brachial Artery Radial Artery and Ulnar Artery The chest piece contains...

Страница 7: ...ith your training model Blue Phantom ultrasound training models are constructed using our patented simulated ultrasound tissue and mimics the imaging characteristics to that of human tissue Care must...

Страница 8: ...ng and place the platform on a clean hard flat surface 2 This model is designed for ultrasound guided technique training You may mark your model with a dry erase marker at your own risk Blue Phantom r...

Страница 9: ...es or permanent damage to your model may occur 3 Smaller bore needles 21 gauge can bend during use and damage your model s simulated tissue 4 Aggressive repositioning of needles rather than removing a...

Страница 10: ...ssels is to have users inject the accessed fluid back into the model after accessing the targeted vessel This is limited to users that are not performing the entire catheter placement procedure CAUTIO...

Страница 11: ...d continue as mentioned above 3 If you still see air present in the junction between arm and chest piece elevate the platform at a 45 degree angle One person may need to hold the arm piece and another...

Страница 12: ...m tissue insert and line up the connectors and gently connect them together Cleaning Your Training Model After each use your training model can be easily cleaned using mild soapy water For best result...

Отзывы: