Blue Ox OX2500D Series Скачать руководство пользователя страница 7

(866) 455-2135

blueoxaircleaners.com

 

[email protected]

 

Blue Ox is a Product of Air Cleaning Specialists, Inc.

 

BLUE OX products are designed to improve your environment. The OX2500D series collects dust, smoke, oil mist, 

oil smoke, and other atmospheric pollutants in industrial plants, shops, schools, and factories with high efficiency, 

2 or 3 stage filtration. It is a complete air filter packaged unit that can be installed easily and used as a free 

hanging air filter unit to clean the ambient pollutants, smoke and haze. 
The OX2500D 

consists of a 4” pleated pre

-filter that traps dust and larger particles. The second stage, micro-glass 

multi-pocket bag filter has 98% arrestance and either 65 or 95% efficiency (depending on the application) on the 

atmospheric dust spot test, removing smoke and other submicron size particles from the air. Changing 

out the

 

filters is easy as it requires no tools. The 4” pre

-filter pulls from the unit and can be replaced. The 

main filter is

 

located directly behind the 4” pre

-filter and pulls out also. For light odors, there is an optional 2

” 

50% bypass 

carbon filter available. 

MOTORS 

All direct drive motors are protected with automatic restart overload protection. 

All belt driven units must be protected externally. 

OPERATION 

Do not operate your units without filter for more than a few minutes at a time. 

MAGNEHELIC PRESSURE GAGE OPTION 

This is an option to help determine when to change the filters. As the bags fill with contaminants, the needle on 

the gage will rise. We recommend changing the bags between 1.25 

 1.50 above the reading with clean filters. It is 

normal to change the pleated twice (or more) as much as the inside bag filter. After the pleated has been change 

and there is no longer a drop in pressure, then it is time to change main filter. The reading may vary depending 

upon the contaminants. Please consult your Sales Engineer for further information. 

FILTERS 

All units are equipped with replaceable type media filters. In some cases, where contaminants being picked up are 

dry, it is possible to blow the pre-filters and reuse them. Filters are available in a number of different degrees of 

efficiencies. The filters in your new OX2500D unit have been selected by your representative to best collect your 

particular type of contaminant. 
Media type filters actually become more efficient as they load with contamination. However, as the filters load up, 

the air flow volume will decrease and eventually will reach a point where they must be replaced to restore the 

original air flow. Changing the filters in your new OX2500D air cleaner is easy. Old filters are simply pulled out of 

the entrance end of the unit and new filters are installed. No tools are required. Turning the unit on when 

installing new filters will help to pull them into place. 

GENERAL NOTE: CLEANING AND INSPECTION OF CABINET 

After the dirty components have been removed, inspect the cabinet interior. Remove foreign material, wipe 

interior, and clean all filter seating surfaces. 
When installing new filters the opening in the bag filter and the pre-filter should be in a vertical position. Be sure 

the cloth part of the bag does not bunch up between the bag header and the angle iron filter stops on the cabinet. 

The pre-filter should be installed with the wire mesh to the inside of the unit. Replacement filters can be supplied 

by your representative. 

LOUVERS 

Four way lovers are provided on all units to permit you to direct the discharge air away from pilot lights or heaters 

and to help you obtain the best air flow pattern for maximum cleaning. 

PARTS 

ALWAYS USE BLUE OX REPLACEMENT FILTERS & PARTS TO MAINTAIN WARRANTY. 

TO ORDER REPLACEMENTS PARTS:  CALL 866-455-2135 |EMAIL [email protected]

11088 Gravois Industrial Court

St. Louis

, MO 63

128

 

Содержание OX2500D Series

Страница 1: ...E THIS MANUAL COMPLETELY AND COMPLY AS DIRECTED ALL THE POTENTIAL HAZARDS OF DUST AND MIST CONTROL SYSTEMS AND EQUIPMENT ARE IMPOSSIBLE TO LIST THEREFORE OBTAIN THE SERVICES OF A PROFESSIONAL INSTALLE...

Страница 2: ...00D CFM Max 1800 with HEPA PSC Type H P Direct Drive with thermal overload 62 dBA Two Speed Switch 10 by 10 Direct Drive Centrifugal Forward Curve Louver with four way individually adjustable blades B...

Страница 3: ...3 Installation of this unit in applications where there is a chance for heated and or flammable materials to enter the unit should be evaluated to determine if a fire protection extinguishing system...

Страница 4: ...cal requirements you should follow the National requirements If the optional Drain Plug was installed in your unit you can connect an appropriate 3 8 I D rubber hose for oil mist routing All chains ho...

Страница 5: ...ai n S wi n gi n g t o C eili n g R o of Tr uss O pti o n 2 M o u nti n g Str ut C h a n n el O X 2 5 0 0 I nst all ati o n M o u nti n g O pti o ns AI R F L O W 2 4 2 4 5 9 Str ut C h a n n el I nst...

Страница 6: ...66 455 2135 blueoxaircleaners com Option 3 Wall Mounting with L Brackets Bolt Unit to L Bracket Lag Screw to Wall Stud Bolt with Spreader Nut if no Stud Block Wall Front Filter Side L Brackets should...

Страница 7: ...ilter The reading may vary depending upon the contaminants Please consult your Sales Engineer for further information FILTERS All units are equipped with replaceable type media filters In some cases w...

Страница 8: ...866 455 2135 blueoxaircleaners com info aircleaningspecialists com Blue Ox is a Product of Air Cleaning Specialists Inc OX2500D Wiring Diagram...

Страница 9: ...866 455 2135 blueoxaircleaners com info aircleaningspecialists com Blue Ox is a Product of Air Cleaning Specialists Inc OX2500D with 3 speed Switch Wiring Diagram...

Страница 10: ...24 X 24 X 4 Pre Filter Pleated MERV 8 9 BOF 4404 AM 24 X 24 X 4 Pre Filter Aluminum Mesh 10 BOF 443668 24 X 24 X 36 65 Bag Filter 8 Pocket 11 BOF 443698 24 X 24 X 36 95 Bag Filter 8 Pocket 12 BOF 4415...

Страница 11: ...ion but not as required low or no airflow Check and open all dampers if installed Check ducting for blockage if installed Check for dirty or blocked filters refer to Maintenance section Check rotation...

Страница 12: ...r Check heater rating against motor nameplate current rating Check motor load If the motor has manual re set thermal protector check if it has been tripped Motor may be overloaded Reduce load Increase...

Страница 13: ...ring connections transformer Worn damaged dirty or overloaded bearings Replace check loading and alignment Loose or defective or out of balance air mover Tighten set screw s repair or replace Insuffic...