- 5 -
M
AINTENANCE
WARNING
Always exercise the stopping procedure before
servicing or lubricating the unit.
After servicing the unit, replace and fasten all
guards, shields, and covers to their original
positions before resuming operation.
CAUTION
Always verify fluid levels and check for leaks after
changing fluids.
Do not drain oil onto ground, into open streams,
or down sewage drains.
Maintenance Schedule
1.
Check all hardware after the first 5 hours of use, then follow the maintenance schedule.
Fluid Levels.)
Changing Exciter Oil
1.
Rotate drum until the fill/drain plug is at bottom of
drum. The fill/drain plug is the larger, square head
plug on the vent side of the roller.
2.
Place drain pan under plug and remove both plugs.
3.
Raise driven side of drum several inches so all oil can
drain out.
4.
After all oil has drained, return drum to a level
surface.
5.
Rotate drum until fill/drain plug is at the top of the
drum.
6.
Remove oil check plug from bottom of cover. The oil
check valve is smaller than the fill plug, and it has an
allen head drive as opposed to the square head
found on the fill/drain plug.
7.
Fill exciter with Oil until oil starts to drain from oil
check plug. See chart for proper amounts.
8.
Replace both plugs.
SYSTEM
MAINTENANCE
EACH USE
EVERY 50
HOURS
EVERY 250
HOURS
YEARLY
Exciter
Check oil level
X
Check for oil leaks
X
Change oil
X
X
Tighten Bolts
1
X
X
Hardware
Check and tighten as needed
1
X
X
Shock mounts Check for cracks or tears
X
X
SYSTEM
FLUID VOLUME
RECOMMENDED OIL
73” Exciter
80 oz.
CALL
84” Exciter
128 oz.
CALL
2LO)LOO'UDLQ
$FFHVV3OXJ
'21275(029(
2LOFKHFNSOXJ
224515 32 Oz. Bottle Exciter Oil
224515 32 oz. Bottle Exciter Oil
Содержание 124010
Страница 3: ...This Page Intentionally Left Blank...
Страница 13: ...10 This page intentionally left blank...
Страница 15: ...12 Drum Assembly...
Страница 17: ...14 11 26 27 28 30 29 19 9 20 22 14 24 25 5 2 1 12 13 15 3 1 6 16 17 8 7 10 23 21 4 18 23 Main Assembly...