11
5.1.5 Controls for MIG welding
1
Current adjustment
2
Voltage adjustment
3
Welding mode switch
4 VRD = Voltage Reduction Device indicator light safety feature to reduce OCV for improper MMA connection to operator.
5 MMA
–
SMAW mode
6 SYN-synergize voltage and ampere automatically
7 MANUAL-manually adjust voltage and ampere in GMAW/FCAW mode
8 Temperature overload indicator light , after cooling down, machine can work again.
Note:
this MIG welding machine MIG welding can be both synergic and separate, select the wire feed speed the voltage
parameter will be matched automatically.
Please select the wire diameter according to the wire you use.
Voltage refine initialization value is 0, refine the voltage by
±
1V according to different kinds of gas.
2
4
1
3
5
6
7
8
Содержание IGBT BLUEARC 140MSI
Страница 1: ...OWNER S MANUAL THE IGBT SERIES OF MIG MAG BLUE DEMON BLUEARC 140MSI...
Страница 6: ...5 Block Diagram INPUT CONTROL...
Страница 13: ...12 6 Welding settings quick reference chart...
Страница 26: ...25 12 CONNECTION DIAGRAM OF THE MACHINE...
Страница 27: ...26 13 EXPLOSION DRAWING...