background image

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start
or run

Pump starts and
stops too often

Pump shuts off 
and turns on
independently of
switch (trips thermal
overload protection)

Pump operates
noisily or vibrates
excessively

Pump will not shut
off

Pump operates but
delivers little or no
water

1. Water level too low

2. Blown fuse or tripped circuit

breaker

3. Low line voltage

4. Defective motor
5. Defective float switch
6. Impeller (pump filled with debris)
7. Tangled switch

8. Insufficient liquid level

1. Backflow of water from piping
2. Faulty float switch
3. Check valve not installed or

leaking

4. Discharge head is less than

manufacturer's minimum

1. Excessive water temperature
2. Defective switch or entangled

switch is causing pump to run dry

3. Low line voltage

1. Worn bearings
2. Debris in impeller cavity or

broken

3. Piping attachments to building

structure too rigid or too loose

1. Defective float switch
2. Float switch movement restricted

3. Restricted discharge (obstruction

in piping)

4. Excessive inflow or pump not

properly sized for application

1. Low line voltage

2. Debris caught in impeller or

discharge

3. Worn or defective pump parts or

plugged impeller

4. Pump running backwards
5. Pump not properly sized for

application

6. Check valve stuck closed or

installed backwards

7. Shut off valve closed

1. Pump switch will not turn on unless water covers top of

pump

2. If blown, replace with proper sized fuse or reset breaker

3. If voltage is under recommended minimum, check wiring size

from the main switch on property. If OK, contact power
company.

4. Return for service or replace motor
5. Replace float switch
6. If impeller will not turn, remove housing and remove debris
7. Arrange switch so the switch moves freely. Reposition pump

if necessary

8. Make sure liquid level is at least 13" from the basin floor

1. Install check valve
2. Replace float switch
3. Remove and examine check valve for proper installation and

free operation

4. Recheck all sizing calculations to determine proper pump size

1. Pump should not be used for water above 120°
2. Replace or reposition pump

Pump may start unexpectedly.

Disconnect power supply before

servicing

3. If voltage is under recommended minimum, check wiring size

from the main switch on property. If OK, contact power
company

1. Return for service or replace
2. Remove housing, clean impeller and/or replace broken

impeller

3. Replace portion of discharge pipe with flexible connector

1. Replace float switch
2. Reposition pump or clean basin as required to provide

adequate clearance for float

3. Remove pump and clean pump & piping

4. Recheck all sizing calculation to determine proper pump size

1. If voltage is under recommended minimum, check wiring size

from the main switch on property. If OK, contact power
company

2. Remove, clean and check for tightness

3. Replace worn parts or entire pump. Clean parts if required

4. Check rotation. (CCW from bottom) Return if CW
5. Recheck all sizing calculations to determine proper pump size

6. Remove and examine check valve for proper installation and

free operation

7. Open valve

www.blueangelpumps.com

4

Operating Instructions and Parts Manual

For Replacement Parts, call 1-888-636-6628

Please provide following information:

- Model number
- Serial number (if any)
- Part description

Address parts correspondence to:

Blue Angel Pumps
101 Production Drive
Harrison, OH   45030  U.S.A.

Отзывы: