background image

TRI

PURO

P R E M I U M   F I LT E R   S Y S T E M

 

Turn on the water supply and 

 

check for leaks. It is recom-

mend that you flush at least 2 litres of 

water through the system. Write

the installation and filter change dates 

on the label.

•   On installation allow room 

  around the clamp ring to grip 

  and rotate

•   Minimum 30mm vertical 

  clearance below base of 

  housing for cartridge change

•   On replacing cartridge in 

  sump, align arrow on 

  cartridge top metal plate with 

  arrow on sump– insert  and 

  rotate clockwise as per “IN” 

  arrow to stop

•   To reconnect to head, align 

  arrows on head and sump,

  push sump into head and 

  rotate clamp ring anti-

 clockwise

•   Apply new change date label 

  over existing main product 

 label

 

 

The filter feeds from the outer 

 

 

most push fit fitting (on the 

right when viewed from the front, 

marked ‘in’). Cut the ¼” O.D. inlet/

outlet tubing (not supplied) to the 

correct lengths, ensuring the cut ends 

are square and clean.
 

A

 - Fit the outlet tubing to the ‘

out

’  

 connector.
 

B

 - Fit the inlet tubing to the ‘

in

’  

 connector.

To remove a tube, simply push down on 

the collet whilst pulling on the tubing.

For optimal performance, please follow the instructions in this installation guide.

Using a 

TRI

PURO system outside of these operating parameters may result in poor

performance and could invalidate the warranty.

Valved Head Installation Guide

TRI

PURO

P R E M I U M   F I LT E R   S Y S T E M

1

 

Select the ‘snap fit’ or  rotary 

 

wall plate mounting. 

Please 

note, the rotary wall plate should be 

used if varying positions are required.

5

A

B

3

 

Screw the ‘snap fit’ bracket or 

 

rotary wall plate into the 

marked location. If the rotary wall plate 

option has been used, attach the 

bracket to the wall plate at the required 

angle, using the screw provided. Always 

ensure the location lug is pointing 

upwards.

 

Locate the filter head into the 

 

bracket until you feel it click 

into place (it will only fit one way - with 

the black  location arrows directly 

facing you).

2

 

Measure & mark  the  centres  

 

of your desired filter location.

6

4

Installation/Replacement Tips

•   Change cartridge at not more 

  than 6 monthly intervals

•   Change cartridges when 

  capacity is reached or when 

  pressure falls below 10psi

•   Flush for 2 minutes following

  initial installation and

  cartridge change

Operation Tips

Do not use with water that is microbiologically unsafe or of

unknown quality without adequate disinfection before or

after the system. Install in cold water applications only.

The contaminants removed by this water filter are not 

necessarily present in all water. Systems certified for cyst 

reduction may be used on disinfected water that may 

contain filterable cysts.
For cooler applications only, not intended for use in general 

plumbed-in applications.
We recommend regular replacement of the filter cartridges - change the 

cartridge at least every 6 months.
Do not install if water pressure exceeds 120psi. If your water pressure exceeds 

80psi, you must install a pressure limiting valve. Do not install where water 

hammer conditions may occur. If water hammer conditions exist you must 

install a water hammer arrester. Contact a plumbing professional if you are 

uncertain how to check for these conditions. Installation and use must comply 

with all state and local plumbing laws and regulations. Improper installation 

may result in property damage due to water leakage.

Warning