Maintenance Flow Chart of the Transmitting Issue:
(
NO launch
)
Connect the PC and the phone with maintenance line,
then making the phone into the RF state with META software
Check
Transceiver
to see
if IQ signals exist.
`
Check the
PA output
to
see if there is RF signal in
the path.
Y
Check
CPU
N
Check RF coaxial
switch or matching
network.
Y
Check the
Transceiver
to see if there is RF
signal output.
N
VBAT,PA_EN,BAN
DSW_DCS,VAPC
是否
OK?
Replace
PA
Y
Check CPU
Y
Check
Transceiver if LE
、
SCLK/SDAT
、
RFVCOEN
、
VCXOEN
have the correct signal
.
N
N
N
N
Y
Replace
Transceiver