Assembly instructions:  Hera

Primus PRO

11

Further information

Attention! Important notice:

Installation and assembly of electrical devices may only be carried out by a qualified electrician. Failure to observe the assembly and installa-

tion instructions can result in fire or other dangers. 

Safety Instructions

The Hera+ Actor fits all conventional distributors with a valve connection M 30 x 1.5 mm. 

Mounting on the valve

Hereby blossom-ic GmbH & Co. KG declares that the following products: Hera+ Thermostat HPT-3975, Hera+ Actor HAC-3974, Hera+ Primus 

PRO HPPR-4020 and Gateway GT-100 GS-3996 are in compliance with the essential requirements and the other relevant provisions of Directive 

2014/53/EU. The complete declaration of conformity can be found at the following address: www.blossomic.de/downloads Declaration of 

conformity.

Declaration of conformity

Note: 

When the batteries are empty and the ther-

mostat switches off, the heating continues 

to operate in the last activated mode. Frost 

protection (6 ° C) is activated to prevent the 

heating from freezing and the rooms from 

cooling down unintentionally. 

What is to be done? 

To restore normal operation, please change 

the batteries immediately. The system has 

a memory function that automatically re-

stores the heating program that was set last. 

The devices are not suitable for children and must not be used as toys. Store and dispose of packaging materials in a child-resistant manner. 

Do not disassemble the devices, as they do not contain any user-serviceable parts. If the error code E1, E2 etc. is shown on the display or other 

defects occur, please return the thermostat to the dealer. 

These appliances may be used by children over 8 years of age and by persons with reduced physical, Sensory or mental abilities or lack of 

experience and knowledge, provided that they have been supervised or instructed in the safe use of the appliances and understand the risks 

involved. Children must not play with the equipment. Cleaning and user maintenance must not be performed by children without supervision

Warning notice

The Hera+ Primus PRO Tres Set is suitable exclusively for controlling underfloor heating systems. The regulation of e.g. cooling circuits, radia-

tors is not permitted and can lead to damage.

Intended use

Valve protection function: 

The system opens and closes the valves au-

tomatically once a week, thus ensuring that 

the valves do not get stuck or block.

Reset radio underfloor heating bar to factory settings

Press the reset button on the radio underfloor heating bar for 30 seconds -> LED diode starts to flash -> The bar must be registered again with 

the gateway and therefore the connected thermostats with the bar.

Содержание HERA+ PRIMUS PRO

Страница 1: ...ne basic module in combination with the Hera radio room thermostats Hera Direct room thermostats and the Hera actuators Optional connection of the Hera return temperature sensors With digital hydrauli...

Страница 2: ...f the radio underfloor heating bar 4 Register the Hera thermostat with the bar and assign a port 4 Assign multiple ports to a thermostat 6 Download of the blossomic App 7 Technical data 8 Settings key...

Страница 3: ...up continuously Internet connection successfully established 1 2 3 4 5 Note Functioning in the home safe area Internet connection is used for convenient setting and control via the smartphone The sys...

Страница 4: ...turn temperature Sensors are required for a room with several circles These ensure that there are no cold spots in the room A re turn temperature Sensor is required for each circuit in this room Regis...

Страница 5: ...current room temperature etc 8 9 7 If registration to the Hera Primus PRO bar fails the screen will continue to display REG Press a button on the thermostat again and it will try to connect to the ba...

Страница 6: ...l the thermostat shows the last registered port After a short time SET appears Press the Sleep button again Use the arrow keys to select the desired port 1 2a 3 4 2b 5 Thermostat shows Suc Registratio...

Страница 7: ...s and oth er parameters can be set easily and conveniently via the app Important notice In order to guarantee the smooth functionality of all thermostats and devices as a unit all components including...

Страница 8: ...s PRO Technical data Hera Thermostat Setpoint range Ambient temperature Ambient humidity Battery intake Dimension Wireless frequency Protection class type RF Test CE RoHs Type of antenna 6 30 C 0 50 C...

Страница 9: ...Arrow key Arrow key Set temperature Motion Sensor Heating program Eco current Heating program current temperature Heating program Comfort Heating program night setback Time On Off Press for 3 seconds...

Страница 10: ...movement after 10 minutes the program switches back to Comfort mode If the Sensor is deactivated only possible via the app the temperature remains constant until the next switching phase Com fort or...

Страница 11: ...cally re stores the heating program that was set last The devices are not suitable for children and must not be used as toys Store and dispose of packaging materials in a child resistant manner Do not...

Страница 12: ...blossom ic GmbH Co KG Oberer Buxheimer Weg 60 87700 Memmingen Germany P 49 8331 756 965 80 E info blossomic de W www blossomic de...