Assembly instructions: Avalon Combo
+
9
Further information
Note:
When the batteries are empty and the ther-
mostat switches off, the heating continues to
run in the mode last activated, to prevent the
heating from freezing and the rooms from
cooling down unintentionally, the frost pro-
tection (6°C) is activated.
What is to be done?
To restore normal operation, please replace
the batteries immediately. The system has
a memory function that automatically re-
stores the last heating program set.
Valve protection function:
The system opens and closes the valves au-
tomatically once a week, thus ensuring that
the valves do not get stuck or block.
Attention! Important notice:
Installation and assembly of electrical devices may only be carried out by a qualified electrician. Failure to observe the assembly and installa-
tion instructions can result in fire or other dangers.
Safety Instructions
The Avalon Combo+ actuator fits valves with an M 30 x 1.5mm connection. Suitable makes: Heimeier, Junkers, Landys & Gyr, MNG, Honeywell
30 x 1.5, Herz 30 x 1.5 and Oventrop 30 x 1.5.
Adapter:
To mount the Avalon Combo+ actuator on Danfoss valves you need an adapter (e.g. from Heimeier):
Heimeier 9700-24.700 (Adapter for Danfoss RAV/L-valves)
Heimeier 9702-24.700 (Adapter for Danfoss RA-valves)
Heimeier 9800-24.700 (Adapter for Danfoss RAV-valves)
For all other valves, please use the different adapters of the respective manufacturers. These are available from specialist dealers on request.
We recommend metal adapters for exact functionality!
Mounting on the valve
Herewith blossom-ic GmbH & Co. KG hereby declares that the following product: Avalon Combo+ ACSE-3979 is in compliance with the essen-
tial requirements and other relevant provisions of Directive 2014/53/EU. The complete declaration of conformity can be found at the following
address: www.blossomic.de/downloads Declaration of conformity.
Declaration of conformity
Reset thermostat to factory setting
Switch off the thermostat -> Press the up arrow key until SET and a number appears -> Select „0“ with the arrow keys -> Confirm with the
comfort key -> Switch the thermostat on again („REG“ appears in the display), it must then be registered again.