RATING

TEMP.

MOD-200 OR MOD-200T MODELS.

SPECIFICATIONS AS THE STANDARD

SUFFIX HAVE THE SAME ELECTRICAL

ALL MODELS WITH A 'D' OR 'DM'

'D' MODELS ONLY

INTERNAL N.P.T.

1/2 INCH

         WELLS/BLOOMFIELD * VERDI, NV

PANEL

CONTROL

MASTER

ELECTRICAL CODES.

NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND

 

volts to ground.

2. Do not connect to a circuit operating at more than 150

Panel. Check nameplates for voltage and phase.

knockout to terminal block supplied within the Master Control

supply leads (see 'wiring requirements' label) through conduit

1. Final connection is accomplished by bringing proper power

TO WIRE:

 

3. Connect 1'' drain connection to suitable drain line.

female N.P.T. drains.

2. Warmers with 'D' suffix are supplied with individual 1/2''

end of the manifold.

discretion of the fabricator. Install and tighten pipe plug in one

"DM" and "TDM" units. Location of valve handle is at the

1. A drain manifold complete with valve is supplied on all Model

TO PLUMB:

 

supplied.

4. Mount Control Panel onto electrical box using screws

FRONT PANEL CUTOUT

TOP CUTOUT

SCREWDRIVER

COUNTERTOP

WELLSLOK

GASKET

WARMER FLANGE

FRONT OF THE FIXTURE.

MANIFOLD ARE LOCATED TO THE

THE CONTROL PANEL AND DRAIN

MOUNT APPLIANCE SO THAT BOTH

IMPORTANT:

3. Mount Control Box to apron cutout as shown in drawing.

required to secure flange tightly to countertop.

Wellslok frame and twist "ears" outward (clockwise) as

2. From underneath, insert screwdriver into "slots" in

flange.

to underside of gray gasket material supplied on mounting

to countertop, apply a bead of silicone adhesive/sealant

RECOMMENDATION: Before final seating of modular section

modular section into countertop cutout and position.

countertop cutout, then through apron cutout. Lower

1. Tilt and pass Control Panel and electrical box through

Master Control Panel when making installation.

IMPORTANT - DO NOT disconnect "lead wires" from the

TO INSTALL:

 

4. Unit shall be accessible for servicing from the bottom.

3. Cut out holes. 

apron using control box as a template.

2. Layout and fabricate control panel holes in counter

apron.

1. Layout "cutout" dimensions on countertop and front

TO FABRICATE:

 

the unit to avoid contact with elevated temperatures.

recommended that a baffle be placed 8 1/2 inches below

3. If storage is to be used underneath the unit, it is

2. Unit shall be accessible for servicing from the bottom.

may be 1 inch.

control box is located below the unit, the front clearance

and 6 3/4 inches to a surface below the unit. If the

4 1/8 inches to front wall, 1 inch to back and side walls,

Wooden and Metal Installation: DO NOT install closer than

1. Required Installation Clearances:

OUTLINED BELOW UPON INSTALLATION:

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

 

IS SUPPLIED FOR DM AND TDM MODELS ONLY.

THE DRAIN MANIFOLD WITH 1" INTERNAL NPT VALVE

NOTE:

CUTOUT DETAILS

INSTALLATION INSTRUCTIONS

         37099-2     REV (-)

INSTALLATION INSTRUCTIONS

BUILT-IN MODULAR WARMERS

MOD 200 SERIES (T, TD, TDM)

12 AWB Cu

FIELD

WIRING

GAUGE

SINGLE

8.7

208

1800

MOD-200

AMPS

VOLTS

WATTS

MODELS

PHASE

12 AWB Cu

SINGLE

10.0

240

2400

MOD-200

14 AWB Cu

SINGLE

11.9

208

2480

MOD-200T

14 AWB Cu

SINGLE

13.8

240

3300

MOD-200T

(25)

(25)

(171)

(105)

MINIMUM CLEARANCE REQUIRED FROM

BACK

SIDE

BOTTOM

FRONT

1

1

6 3/4

4 1/8

ELECTRICAL

CLEARANCES

PRODUCT DIMENSIONS

UNIT TO THE NEAREST SURFACE

INCHES

(MM)