Bloomfield Integrity 8752 Скачать руководство пользователя страница 7

INSTALLATION (continued) 

NOTE:

  This equipment must be 

installed to comply with          
applicable federal, state and  
local plumbing codes and       
ordinances. 

 

 

WARNING: 

SHOCK HAZARD

 

 

Brewer must be properly 
grounded to prevent possible 
shock hazard.  DO NOT        
assume a plumbing line will  
provide such a ground.        
Electrical shock will cause death 
or serious injury. 
 

IMPORTANT: 

Supply power must match 
nameplate for voltage and 
phase.  Connecting to the 
wrong voltage will damage the 
brewer or result in decreased 
performance.  Such damage is 
not covered by warranty. 
 

IMPORTANT:

  

Do not connect brewer to    
electrical power until you are 
ready to fill the tank.  See      
instructions on page 6. 

A water shut-off valve should be installed on the incoming water 
line in a convenient location (Use a low restriction type valve, 
such as a 1/4-turn ball valve, to avoid loss of water flow thru the 
valve. 

 
NSF requires that the brewer be able to be moved for cleaning 
underneath.  A flex line or loops of copper tubing will satisfy this 
requirement. See Figure 2 below. 
 

 
 
 
 
 
 
 
 
 
 
 

In some areas, local codes require a backflow preventer  (check 
valve)  to be installed on the inlet water line.  If a backflow        
preventer is used, you must install a 

water hammer arrester 

in 

the incoming line, between the backflow preventer and the 
brewer inlet, as far away from the brewer as space will allow.  
This will relieve the excessive back  pressures that can cause 
faucet leaks and solenoid malfunctions.  
 

ELECTRICIAN’S INSTALLATION INSTRUCTIONS 

 
REFER TO ELECTRICAL SPECIFICATIONS  -  Page  1 
Check the nameplate to determine correct electrical service 
required for this installation. 

 

IMPORTANT:  

Before connecting to electricity, make sure the 

brewer is connected to the water supply.   

 

IMPORTANT: 

For power supply connections use COPPER WIRE only. Wiring 
must be suitable for at least 75ºC.  This brewer requires a      
dedicated electric circuit. 

 

Models 8752 

must be wired by an electrician, and require a 

115/230V 20A circuit (50/60 Hz,  2 hot legs / 1 neutral leg, plus 
ground).  Remove rear panel to gain access to terminal block.  
Green terminal must be connected to a suitable building ground.  
Circuit must be capable of 4000 Watts.   See figure 3 at right. 

 

IMPORTANT:  

Wiring must be installed in approved solid or  

flexible conduit, and must be secured to the brewer with a strain 
relief (to be provided by the installer). 

Fig. 2  Water Supply Installation

 

Fig. 3  Electrical Installation

 

605 7098

O

w

n

e

rs 

M

anua

 Int

e

gri

ty 5

W

 Decan

ter Brew

er

 

Содержание Integrity 8752

Страница 1: ...605 OWNERS MANUAL for INTEGRITY 5 WARMER COFFEE BREWERS MODEL 8752 8752KFT Includes Installation Operation Use Care Servicing Instructions Model 8752 Brewer with optional 8900 Series Decanters p n 70...

Страница 2: ...s warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A P...

Страница 3: ...this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFICATIONS 1 FEATURES OPERATING CONTROLS 2 PREC...

Страница 4: ...FEATURES AND OPERATING CONTROLS 2 Fig 1 Model 8752 Features and Operating Controls 605 70988 Owners Manual Integrity 5W Decanter Brewer...

Страница 5: ...ce is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and unde...

Страница 6: ...ewer must be installed on a water line with average pressure between 20 PSI and 90 PSI If your water pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line...

Страница 7: ...et water line If a backflow preventer is used you must install a water hammer arrester in the incoming line between the backflow preventer and the brewer inlet as far away from the brewer as space wil...

Страница 8: ...er into the pour over opening until water flows from the brew head When water stops dripping from the brew head empty the container Once the tank is full of water connect the brewer to electrical powe...

Страница 9: ...on energizes the solenoid valve allowing water from an external water supply to flow into the basin pan and then into the hot water tank This forces an identical amount of hot water out of the tank an...

Страница 10: ...ith tap water Lift the pour over cover and pour the entire contents of the decanter into the pour over opening which will fill the basin Water from the basin will displace a like amount of heated wate...

Страница 11: ...e brush may be used to clear clogged spray holes Rinse the spray disk with clean water and allow to air dry 7 Wash the brew chamber in a sink using warm water and a mild detergent A bristle brush may...

Страница 12: ...d Damaged internal component or wiring No water or too little water added at start up Not enough water poured in Too much coffee grounds Timer out of adjustment Too many filter papers or wrong filter...

Страница 13: ...PANELS Remove upper front panel to access timer and hi limit Remove button plugs for simple adjustments or reset Upper front panel is held by two screws at the bottom and a retaining lip at the top S...

Страница 14: ...hese procedures are to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTANT A mechanical thermostat will maintain temperat...

Страница 15: ...clockwise increases time Run several cycles to check amount of water delivered Replace button plug REMOVE TANK LID ASSEMBLY Unplug brewer or turn circuit breaker OFF Turn OFF water supply Remove top...

Страница 16: ...he hose to be easily slid off of the solenoid bypass outlet Transfer solenoid bracket to new solenoid Reinstall hose by pressing end of hose onto bypass outlet until it is fully seated Reassemble in r...

Страница 17: ...at cup Clean out any debris in the faucet body using a stiff bristle brush if necessary Examine the aerator Clean any debris from the screen or flow straightener using a stiff bristle brush if necessa...

Страница 18: ...ropriate work area 1 Unplug power cord Turn off the water shut off valve and disconnect the water supply line from the brewer inlet fitting 2 Remove the tank lid assembly as described on page 13 3 Rem...

Страница 19: ...then reinstall the top panel 10 Reconnect brewer to electrical supply and reconnect water supply 11 Install the brew chamber without filter paper or grounds Run at least three full brew cycles and dis...

Страница 20: ...ASSEMBLY BASIN BODY 102 8542 6 COVER BASIN TOP INCLUDES 86666 POUR OVER ASSY 103 86666 ASSEMBLY POUR OVER PLASTIC 108 8541 21 BASIN 110 8751 17 PLATE BOTTOM 8750 SERIES 111 ASSEMBLY BODY 8750 SERIES...

Страница 21: ...ARY 31 8528 40 SWITCH TANK HEATER 240V 20A 32 8738 2 INDICATOR LIGHT 120V GREEN 35 8718 1 TIMER W KNOB 2 MIN 36 8552 18 TERMINAL BLOCK 4P 39 86945 SWITCH WARMER 45 85685 SOLENOID 120V W BYPASS 75GPM 5...

Страница 22: ...3 28 NUT HEX 1 2 20 BRASS 56 8043 30 GASKET SEAL 57 8941 21 NUT HEX 7 16 20 BRASS 58 8540 6 HOT WATER COIL 59 8043 8 ELBOW INLET 60 8043 15 VENT TUBE 61 8043 11 ELBOW OUTLET 62 8514 68 TANK COVER 8 HO...

Страница 23: ...16 20 Ni 27 8551 100B WASHER LOCK 7 16 28 82681 WASHER FLAT 15 32 x 1 1 8 x 048 SS 29 85778 ASSEMBLY BRAIDED TUBE W BALL VALVE 14 33 8543 42 GASKET SPRAYHEAD 34 82727 SPRAY DISK EMBOSSED 34A 8543 85...

Страница 24: ...12d Spring 12h Stem 12j Pin 12k Bonnet 82682 Retainer Clip item 12b 84804 Aerator Replacement Kit Includes 12e O Ring 12f Aerator Disk 12g Aerator Cap 84870 Aerator Repair Kit Includes 12e O Ring 12f...

Страница 25: ...WIRING DIAGRAM 23 605 70988 Owners Manual Integrity 5W Decanter Brewer...

Страница 26: ...c Division of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly s...

Отзывы: