TROUBLESHOOTING SUGGESTIONS
9
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
No power to warmer
Circuit breaker off or tripped
Reset circuit breaker
Warmer will not heat
Temperature control not set
Set control to desired temperature
Warmer trips circuit breaker
Wet insulation
Verify flange-to counter seal is
sound, or reseal with food-grade
silicone sealant
Pan leaking or other internal
damage
Contact your Authorized Wells
Service Agency for repairs
Internal damage
Contact your Authorized Wells
Service Agency for repairs
Warmer slow to heat
Mineral deposits on pan acting as
a insulator
Clean pan(s) with Wells Delime
Cleaner
Wired to wrong voltage
Verify supply voltage - must
match voltage on warmer
nameplate
Drain-equipped unit will not hold
water
Drain valve not fully closed
Check drain valve for debris and
close fully
Drain valve damaged or pan(s)
leaking
Contact your Authorized Wells
Service Agency for repairs
There are no user-serviceable
components in the control unit or
in the pan shroud. In all instances
of damage or malfunction, contact
your Authorized Wells Service
Agency for repairs.