SERVICING INSTRUCTIONS (continued) 

14 

IMPORTANT: 

Water pressure must be         
between 20 p.s.i and 90 p.s.i. 
flowing pressure. If water     
pressure exceeds this value,    
or if water pressure varies 
greatly, a pressure regulator 
must be installed in the water 
supply line.

 

 
NOTE:  

DELAY is the amount of 

time before a second brew can 
be initiated, and is factory set 
for 5 minutes.  LOCK and 
ALARM are not used. 

 
 
IMPORTANT: 

Before setting assembly into 
tank, make sure tank lid gasket 
is properly seated on flange of 
lid. 

DO NOT OVER-TIGHTEN

.  

 
 
 
 
 
 
 
 

IMPORTANT:   

When mounting thermostat, be 
sure to insert sensing bulb to 
the bottom of the bulb well. 
Tighten capillary lock nut only 
enough to ensure no water  
leakage.  Excessive tightening 
is not necessary.  
 
 
 
 
 

 

IMPORTANT: 

When replacing heating         
element, also replace seal    
gaskets. 
 

TIMER ADJUSTMENT (AUTOMATIC BREWERS ONLY) 

 

The amount of water dispensed automatically during a brew cycle 
is controlled by the timer. 

 
Place empty decanter (for Model 0482, use an airpot) under brew 
chamber.  Press BREW  button.  Brewer should dispense one full 
decanter or airpot of water.  To adjust amount: 

 
Remove brew chamber and button plug.  Adjust knob on timer;  
clockwise increases time.  Run several cycles to check amount of 
water delivered.  Replace button plug. 

 
REMOVE TANK LID ASSEMBLY 

 
Disconnect brewer from electric power.  Turn 

OFF

 water   supply.  

Remove top panel.  Pull vent tube and inlet elbow out of basin 
pan. 

 
On automatic models, pull water inlet tube out of basin pan.     
Remove basin pan. 

 
On models with faucet, disconnect inlet pipe at faucet shut-off 
valve and outlet pipe at faucet. 

 
Disconnect all wiring from thermostat, hi-limit, and heating       
element. 

 
Loosen two nuts on tank hold-down bracket.  Remove hold-down 
bracket by sliding short slotted end off of locking stud and lifting it 
off.  Remove cover assembly by lifting it straight up. 

 
Reassemble in reverse order. 
               

REPLACE THERMOSTAT (COTHERM) 

 
Disconnect brewer from electric power.  Turn 

OFF

 water   supply.  

Remove top panel. 

 
Disconnect all wiring from thermostat only.  Loosen and free jam 
nut from pass-thru fitting securing temperature sensing bulb.   
Remove two screws holding thermostat to bracket. 

 
Lift out thermostat, sensing bulb and thermostat gasket.   

 
Reassemble in reverse order.  BE SURE the bulb well is fully 
seated in the tank fitting, and that the temperature sensing bulb is 
inserted to the very bottom of the bulb well. 

 

REPLACE HEATING ELEMENT 

 
Remove tank lid assembly per above. 

 
Remove two hex nuts holding element to cover.  Pull element 
from mounting holes. 

 
Reassemble in reverse order. 

685

   77110

  Ow

ners

 M

a

n

ual Ho

ri

z

o

n™ Brew

ers 

Содержание Horizon 0412

Страница 1: ...ewer Model 0412 In Line Decanter Brewer Model 0472 Stepped Right Decanter Brewer OWNERS MANUAL For COFFEE BREWERS MODELS 0412 Decanter In Line 0443 Decanter In Line Pour Over 0471 Decanter Step up Pou...

Страница 2: ...ys parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS...

Страница 3: ...ional operation and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains the information needed to p...

Страница 4: ...FEATURES AND OPERATING CONTROLS AUTOMATIC BREWERS 2 Fig 1 Features Operating Controls for Automatic Brewers 685 77110 Owners Manual Horizon Brewers...

Страница 5: ...FEATURES AND OPERATING CONTROLS POUR OVER BREWERS 3 Fig 2 Features Operating Controls for Pour Over Brewers 685 77110 Owners Manual Horizon Brewers...

Страница 6: ...ecommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familiar with the appliance use limitations and assoc...

Страница 7: ...ft to right and front to back by turning the adjustable feet Be sure all four feet touch the counter to prevent tipping IMPORTANT To enable the installer to make a quality installation and to minimize...

Страница 8: ...g will satisfy this requirement See Figure 3 below In some areas local codes require a backflow preventer check valve to be installed on the inlet water line If a backflow preventer is used you must i...

Страница 9: ...l shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the proper circuit and receptacle ELECT...

Страница 10: ...begin heating water in preparation for the first brew When the water has reached the proper temperature the READY light will glow Pour Over Units See Figure 6 at left 1 Insert the brew chamber empty a...

Страница 11: ...will displace a like amount of heated water from the tank The hot water will be forced into the brew head where it will spray over the bed of grounds Freshly brewed coffee will begin to fill the conta...

Страница 12: ...ristle brush may be used to clean the inside Rinse with clean water and allow to air dry 8 For Model 0782 wash the cup grid and cup grid well Reinstall cup grid 9 Wipe the exterior of the brewer with...

Страница 13: ...ow Hi Limit safety switch tripped Damaged internal component or wiring Timer out of adjustment Too many filter papers or wrong filter paper Brew chamber dispense hole plugged Too much coffee or too fi...

Страница 14: ...g and top mounted warmers Top panel is held by screws around the edge FRONT PANEL Remove front panel to access timer Models 0412 and 0443 Front panel and main warmer panel are one piece and are held b...

Страница 15: ...procedures involve exposed electrical circuits These procedures are to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTA...

Страница 16: ...cycles to check amount of water delivered Replace button plug REMOVE TANK LID ASSEMBLY Disconnect brewer from electric power Turn OFF water supply Remove top panel Pull vent tube and inlet elbow out o...

Страница 17: ...d the white ring on the extreme end of the metal hose fitting b Pressure on the white ring toward the metal fitting releases the clinch ring allowing the tube to be easily slid off of the solenoid byp...

Страница 18: ...Pull coil from mounting holes Reassemble in reverse order REPAIR HOT WATER FAUCET Open top panel Turn faucet valve OFF Unscrew aerator cap from faucet and remove handle retaining clip Do not let fauc...

Страница 19: ...14 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solution according to the manufacture...

Страница 20: ...EXPLODED VIEW PARTS LIST 18 PLUMBING RELATED COMPONENTS AUTOMATIC BREWERS MODELS 0412 0472 0482 685 77110 Owners Manual Horizon Brewers...

Страница 21: ...EXPLODED VIEW PARTS LIST continued 19 PLUMBING RELATED COMPONENTS POUR OVER BREWERS MODELS 0443 0471 685 77110 Owners Manual Horizon Brewers...

Страница 22: ...EXPLODED VIEW PARTS LIST continued 20 CABINET ELECTRICAL COMPONENTS AUTOMATIC IN LINE DECANTER BREWER MODEL 0412 685 77110 Owners Manual Horizon Brewers...

Страница 23: ...EXPLODED VIEW PARTS LIST continued 21 CABINET ELECTRICAL COMPONENTS POUR OVER IN LINE DECANTER BREWER MODEL 0443 685 77110 Owners Manual Horizon Brewers...

Страница 24: ...EXPLODED VIEW PARTS LIST continued EXPLODED VIEW PARTS LIST continued 22 CABINET ELECTRICAL COMPONENTS AUTOMATIC STEP UP DECANTER BREWER MODEL 0472 685 77110 Owners Manual Horizon Brewers...

Страница 25: ...EXPLODED VIEW PARTS LIST continued 23 CABINET ELECTRICAL COMPONENTS POUR OVER STEP UP DECANTER BREWER MODEL 0471 685 77110 Owners Manual Horizon Brewers...

Страница 26: ...EXPLODED VIEW PARTS LIST continued 24 CABINET ELECTRICAL COMPONENTS AUTOMATIC AIRPOT THERMAL BREWER MODEL 0482 685 77110 Owners Manual Horizon Brewers...

Страница 27: ...12k Bonnet 82682 Retainer Clip item 12b 84804 Aerator Replacement Kit Includes 12e O Ring 12f Aerator Disk 12g Aerator Cap 84870 Aerator Repair Kit Includes 12e O Ring 12f Aerator Disk SOLENOID REPAI...

Страница 28: ...WIRING DIAGRAM 26 AUTOMATIC BREWERS 685 77110 Owners Manual Horizon Brewers...

Страница 29: ...WIRING DIAGRAM continued 27 POUR OVER BREWERS 685 77110 Owners Manual Horizon Brewers...

Страница 30: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...

Отзывы: