background image

SERVICING INSTRUCTIONS (continued) 

IMPORTANT: 

 Water pressure 

must be between 20 p.s.i and 
90 p.s.i. flowing pressure.         
If water pressure exceeds this 
value, or if water pressure     
varies greatly, a pressure   
regulator must be installed in 
the water supply line.

 

IMPORTANT:  

Before setting 

assembly into tank, make sure 
tank lid gasket is properly 
seated on flange of lid.           

DO NOT OVER-TIGHTEN

.  

 
 
 
 
 

IMPORTANT:  

When replacing 

temperature probe, be sure a 
new seal washer is in place 
around the probe.  Tighten jamb 
lock nut only enough to ensure 
no water  leakage.  Excessive 
tightening is not necessary.  

 

 

 

 

IMPORTANT:  

When replacing 

heating element, also replace 
seal gaskets. 
 

BREW TIME ADJUSTMENT  

 

The amount of water dispensed automatically during a brew cycle 
is controlled by the SOLENOID TIME dial of the controller.   

 
Place empty decanter under brew chamber.  Press BREW      
button.  Brewer should dispense one full decanter of water.  To 
adjust amount: 

 
Remove brew chamber and button plug.  On the controller, adjust 
SOLENOID TIME dial (BREW TIME);  clockwise increases time. 
Run several cycles to check amount of water delivered.  
 

DRIPOUT TIME ADJUSTMENT 

 
Water delivered to the brew chamber will take a while to drip 
through as coffee.  The time between the end of a brew and 
when a new brew can be initiated is controlled by the BREW  
SIGNAL TIMER.  Adjust the BREW SIGNAL TIMER dial on the 
controller to account for the dripout time.  Replace button plug. 

 
REMOVE TANK LID ASSEMBLY 

 
Unplug brewer or turn circuit breaker 

OFF

.  Turn 

OFF

 water   

supply.  Remove top panel.  Pull vent tube and inlet elbow out of 
basin pan. 

 
On automatic models, pull water inlet tube out of basin pan.     
Remove basin pan. 

 
On models with faucet, disconnect inlet pipe at faucet shut-off 
valve and outlet pipe at faucet. 

 
Disconnect all wiring from hi-limit and heating element.            
Disconnect temperature probe from controller. 

 
Loosen center screw on tank hold-down bracket.  Remove    
hold-down bracket by sliding short slotted end off of locking stud 
and lifting it off.  Remove cover assembly by lifting it straight up. 

 
Reassemble in reverse order. 
 

REPLACE TEMPERATURE PROBE 

 
Unplug brewer or turn circuit breaker 

OFF

.  Remove top panel. 

 
Loosen and free jam nut from pass-thru fitting securing            
temperature probe.   Disconnect temperature probe wiring      
connector from controller. 
Lift out probe, jamb nut and gasket. 

 
Reassemble in reverse order. 

 

REPLACE HEATING ELEMENT 

 
Remove tank lid assembly per above. 

 
Remove two hex nuts holding element to cover.  Pull element 
from mounting holes. 

 
Reassemble in reverse order. 

Fig. 14  Adjust BrewTime 
             and Dripout Time 

16 

645 

 75908

 Owner

s M

anual E.B.C. Du

al Airpo

t/Thermal 

B

rewer  

Содержание E.B.C. 1093

Страница 1: ...com p n 75908 Rev E ECN 13385 M645 071107 cps 645 OWNERS MANUAL for E B C Electronic Brew Control DUAL AIRPOT AND THERMAL COFFEE BREWERS MODELS 1090 1091 1092 1093 Includes Installation Use Care Serv...

Страница 2: ...arry a 30 day parts warranty only b dispensers i e tea and coffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXP...

Страница 3: ...3 AGENCY LISTING INFORMATION 3 INSTALLATION INSTRUCTIONS 4 OPERATION 6 BREWING COFFEE 10 CLEANING INSTRUCTIONS 11 TROUBLESHOOTING SUGGESTIONS 12 Error Detection 13 SERVICING INSTRUCTIONS 14 Deliming...

Страница 4: ...FEATURES AND OPERATING CONTROLS Fig 1 Features Operating Controls 2 645 75908 Owners Manual E B C Dual Airpot Thermal Brewer...

Страница 5: ...ntended for use in commercial establishments where all operators are familiar with the appliance use limitations and associated hazards Operating instructions and warnings must be read and understood...

Страница 6: ...ater pressure exceeds 90 PSI at anytime a pressure regulator must be installed in the water supply line to limit the pressure to not more than 90 PSI in order to avoid damage to lines and solenoid Plu...

Страница 7: ...is used you must install a water hammer arrester in the incoming line between the backflow preventer and the brewer inlet as far away from the brewer as space will allow This will relieve the excessiv...

Страница 8: ...er opening until water flows from the brew heads This will require the equivalent of three full 64oz Decanters per side When water stops dripping from the brew head empty the container Once the tanks...

Страница 9: ...head AUTOMATIC OPERATION Pressing the BREW key energizes the solenoid valve allowing water from an external water supply to flow into the water tank The incoming water forces heated water out of the t...

Страница 10: ...d NOTE To override Brew Waiting Mode press and hold the BREW key for 3 seconds while the BREW indicator is flashing Brew will begin regardless of water temperature To avoid under temperature brews thi...

Страница 11: ...hout a brew being initiated Disable Enable After Hours Feature To disable After Hours press the ON OFF key to turn the brewer OFF Press and hold the CANCEL key until two beeps sound and the HEAT indic...

Страница 12: ...g used with tap water Lift the pour over cover and pour the entire contents of the container into the pour over opening which will fill the basin Water from the basin will displace a like amount of he...

Страница 13: ...and a mild detergent A bristle brush may be used to clean the inside Rinse with clean water and allow to air dry For stainless steel brew chambers be sure the wire rack is properly reinstalled 8 Wipe...

Страница 14: ...d too low or set to OFF Hi Limit thermostat tripped Damaged internal component or wiring Timer out of adjustment Too many filter papers or wrong filter paper Brew chamber dispense hole plugged Spray g...

Страница 15: ...p probe Check power board and heating element Brewer will go into error mode 4 minutes after energizing the heating element if insufficient heat rise is detected The heating element is energized by an...

Страница 16: ...heating elements brew circuit tubing faucet valve and piping Top panel is held by two screws at the rear and a retaining lip at the front FRONT PANEL Remove front panel to access controller terminal...

Страница 17: ...ing and Adjusting Brew Temperature CAUTION SHOCK HAZARD These procedures involve exposed electrical circuits These procedures are to be performed by qualified technical personnel only NOTE Optimum bre...

Страница 18: ...ween the end of a brew and when a new brew can be initiated is controlled by the BREW SIGNAL TIMER Adjust the BREW SIGNAL TIMER dial on the controller to account for the dripout time Replace button pl...

Страница 19: ...skets Remove tank lid assembly per above Remove two hex nuts hot water coil to cover Pull coil from mounting holes REPAIR HOT WATER FAUCET Remove top panel and turn faucet valve OFF Unscrew aerator ca...

Страница 20: ...n hi limit until it clicks and stays in Reassemble in reverse order Test for function and proper operation REPLACE CONTROLLER Unplug power cord or turn circuit breaker OFF Remove front panel Remove ti...

Страница 21: ...ibbon cable to provide abrasion resistance where the cable passes through the cabinet Do NOT remove this protective sleeve Slide ribbon cable into slot on basin body from the outside then carefully ap...

Страница 22: ...upply Turn off the water shut off valve and disconnect the water supply line from the brewer inlet fitting On right side tank disconnect faucet fittings 2 Remove the tank lid assemblies as described o...

Страница 23: ...l internal components are dry then reinstall the top panel 10 Reconnect brewer to electrical supply and reconnect water supply 11 Install the brew chambers without filter papers or grounds Run at leas...

Страница 24: ...8 Tank Cover Plate Only 8 holes All Right Tank Only 8512 45 Tank Cover Plate Only 6 holes All Left Tank Only 64 8543 74 Nut Hex 4 40 SS All 65 8543 73 Screw 4 40 x 1 SS Pan Head All 66 8043 24 Water i...

Страница 25: ...Side 50 83644 Temperature Probe All 63 8552 50 Hi Limit Thermostat All 67 8043 14 Tank Heating Element 120V 1500W 1090 1092 8716 1 Tank Heating Element 240V 3500W 1091 1093 85 1080 226 Controller Boa...

Страница 26: ...ead Retainer All 43 8541 46 Water Inlet Tube All 45 85753 Solenoid Valve w Bypass Right Side 85754 Solenoid Single Left Side 59 8043 8 Inlet Elbow All 60 8043 15 Vent Tube All 61 8043 11 Outlet Elbow...

Страница 27: ...8033 56 Cap Adjustable Leg All 81732 Adjustable Leg Assembly All 75 8543 69 Heyco Bushing All 101 Body Welded Assy All 102 Front Panel All 103 Mounting Power Board All 104 85089 Access Door Solenoid...

Страница 28: ...WIRING DIAGRAM 26 MODEL VOLTS WATTS AMPS 1090 120 240 4000 17 1092 120 240 4000 17 645 75908 Owners Manual E B C Dual Airpot Thermal Brewer...

Страница 29: ...RAL IN VALVE B VALVE B HEATER B HEATER B VALVE A VALVE A LINE IN LINE IN HEATER A HEATER A CHASSIS GROUND TEMPERATURE PROBE TEMPERATURE PROBE HI LIMIT HI LIMIT 1 1 HEATING ELEMENT HEATING ELEMENT 1 6...

Страница 30: ...ION CUSTOMER SATISFACTION Wells Bloomfield proudly supports CFESA Commercial Food Equipment Service Association Commercial Food Equipment Service Association PRINTED IN UNITED STATES OF AMERICA WELLS...

Отзывы: