background image

NOTE: DRILL SCREW
CLEARANCE HOLES
IN ASSEMBLY
SEAL HOLES AND
FASTENERS WITH
SILICONE SEALANT

NO.8X5/8 LONG
STAINLESS STEEL PAN
HEAD SCREW. LOCK
WASHER & NUT

COUNTER-TOP

DETAIL 'A'

SEALANT

CLEARANCES

BACK

SIDE

BOTTOM

FRONT

(25)

1

1

(25)

(171)

6 3/4

(105)

4 1/8

SUGGESTED CLEARANCES FROM UNIT

TO THE NEAREST SURFACE

TO FABRICATE AND INSTALL:

1. Lay out cutout dimensions on countertop and apron.

2. Cut and/or drill holes as required in countertop and apron.

3. Turn down flange with square corners (maximum 1/2 inch).

4. To install, position warmer underneath so that turn down is

positioned onto embossed shoulders of warmer. Drill as

required.

5. Remove warmer and apply a bead of silicone sealant to

shoulder area. Remount and secure warmer to fixture with

stainless steel screws (see Detail "A" above).

6. Mount control to apron.

7. Connect supply connection wiring to thermostat. Check

nameplate for correct voltage.

SEE CONDITIONS OF ACCEPTABILITY BELOW.

"SQUARE CORNER" FOOD WARMERS

INSTALLATION INSTRUCTIONS

46033-1   REV (A)

INSTALLATION INSTRUCTIONS

BUILT-IN (BOTTOM MOUNT) INSULATED

MODELS BMW-206ST, STD

WELLS/BLOOMFIELD * VERDI, NV

ELECTRICAL

MODEL

VOLTS

WATTS

AMPS

PHASE

WIRING

TEMP.

FIELD

GAUGE

RATING

BMW-206ST

BMW-206ST

BMW-206ST

BMW-206STD

BMW-206STD

BMW-206STD

240

208

120

240

208

120

1200

1240

1650

1200

1240

1650

10.0

6.0

6.9

10.0

6.0

6.9

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

SINGLE

#14 AWG Cu

#14 AWG Cu

#14 AWG Cu

#14 AWG Cu

#14 AWG Cu

#14 AWG Cu

90°C MIN.

90°C MIN.

90°C MIN.

90°C MIN.

90°C MIN.

90°C MIN.

CUTOUT DETAILS

PRODUCT DIMENSIONS

UNIT MUST BE INSTALLED IN AN ALL METAL COUNTER.

NOTE:  The BMW-206STD warmer is supplied with a drain hole

at one end and a 1/2 inch female N.P.T. drain nipple.

INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY

OUTLINED BELOW UPON INSTALLATION:

1. This appliance shall be installed in an all metal counter with

suitable wiring and control enclosures conforming to national and

local electrical codes.

2. Electrical component temperatures, including wiring, within and

surrounding the appliance must be monitored in the end use

installation for suitability.

3. Electrical grounding of all dead metal parts must be reliably

connected to the grounding means of the appliance and must

comply with requirements outlined in the appropriate Underwriters

Laboratories Inc. classification, national, and local electrical

codes.

4. Increased clearances are required if storage of combustible

materials is in close proximity to this appliance.

5. Unit shall be accessible for servicing from the bottom.

6. The name/rating plate information shall be accessible.

7. For water and waste connections: This appliance is to be

installed to comply with the applicable federal, state or local

plumbing codes.

THE INSTALLATION OF RECOGNIZED COMPONENT UNITS REQUIRES

ADDITIONAL EVALUATIONS TO UNDERWRITERS LABORATORIES INC.

STANDARDS.

METAL SHIELD

1/2 IN DRAIN NPT
BMW-206STD

SQUARE
CORNERS

(MAX TURN DOWN)

TOP CUTOUT

FRONT PANEL CUTOUT

PILOT
LIGHT

9 MIN

(229)

21 13/16

(554)

20 3/32

(510)

12 1/16

(306)

8 5/16

(211)

13 11/16

(348)

1/2

(13)

12 1/32

(306)

20 1/16

(510)

6 5/16

(160)

4 1/8

(105)

7/8

(22)

7/8

(22)

2 1/32

(52)

5/16

(8)

Ø

3/8

(10)

Ø

5/32
(4)

Ø

5/32

(4)

Ø

INCHES

(MM)

Отзывы: